Evidence used
- No CISA KEV confirmation is currently recorded.
- The selected CVSS metric records a network-reachable, unauthenticated path with no user interaction.
- EPSS is 0.69% for the current model date.
BlackTreeCVE IntelligenceArista Networks · EOS
Critical technical impact with a remotely reachable, unauthenticated path; no CISA KEV confirmation is currently recorded.
Critical technical impact with a remotely reachable, unauthenticated path; no CISA KEV confirmation is currently recorded.
Patch availableAn unauthenticated P4Runtime (Programming Protocol-Independent Packet Processors Runtime) client can achieve arbitrary code execution under certain conditions on affected platforms running Arista EOS configured with P4Runtime. P4Runtime is disabled by default in Arista EOS. By crafting a malicious packet during the initiation of a P4Runtime session, an attacker can obtain complete administrative control over the compromised switch. This issue was discovered internally by Arista, and the company is not aware of any malicious exploitation of this vulnerability in customer networks.
An unauthenticated P4Runtime (Programming Protocol-Independent Packet Processors Runtime) client can achieve arbitrary code execution under certain conditions on affected platforms running Arista EOS configured with P4Runtime. P4Runtime is disabled by default in Arista EOS. By crafting a malicious packet during the initiation of a P4Runtime session, an attacker can obtain complete administrative control over the compromised switch. This issue was discovered internally by Arista, and the company is not aware of any malicious exploitation of this vulnerability in customer networks.
Untrusted data can cross into a code-evaluation path and be interpreted as executable instructions.
An attacker operating through a network path may attempt exploitation without authentication or user interaction. If successful, the issue may execute code or commands in the affected security context.
An unauthenticated P4Runtime (Programming Protocol-Independent Packet Processors Runtime) client can achieve arbitrary code execution under certain conditions on affected platforms running Arista EOS configured with P4Runtime. P4Runtime is disabled by default in Arista EOS. By crafting a malicious packet during the initiation of a P4Runtime session, an attacker can obtain complete administrative control over the compromised switch. This issue was discovered internally by Arista, and the company is not aware of any malicious exploitation of this vulnerability in customer networks.
Untrusted data can cross into a code-evaluation path and be interpreted as executable instructions.
An attacker operating through a network path may attempt exploitation without authentication or user interaction. If successful, the issue may execute code or commands in the affected security context.
CVSS severity, EPSS forecast probability, public exploit material and CISA-confirmed exploitation are separate signals.
No CISA KEV match was present at the last successful refresh. This means no confirmation from that source, not proof of no exploitation.
No exploit-tagged reference or CISA SSVC proof-of-concept state is currently recorded. Research may still exist outside the structured feeds.
CWE-94: Improper Control of Generation of Code ('Code Injection'). The product constructs all or part of a code segment using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the syntax or behavior of the intended code segment.
CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:HCommon Vulnerability Scoring System 4.0: the compact vector below is decoded into plain language.
Operational remediation based on structured source evidence.
Published 16 Sept 2026 · Last source change 17 Sept 2026, 03:56 UTC · CWE-94 · Improper Control of Generation of Code ('Code Injection')
Core structured fields are present and their contributing authorities are shown above.