BlackTreeCVE Intelligence
← Back to the CVE catalogue
Full vulnerability report · 2026
CVE-2026-42486High confidence

Multiple RBAC issues in XAPI

Xen · XAPI

9.4CriticalCVSS 4.0
Recommended action
Within 7 days

Critical technical severity; prioritise exposed affected systems while verifying vendor guidance.

Fix not verified
R
Operational reassessment

Published severity in operational context

Open reassessment dashboard →
Published severityCriticalOperational priority:Critical, unchanged from published severity.unchanged

Evidence used

  • No CISA KEV confirmation is currently recorded.
  • EPSS is 0.17% for the current model date.

Compensating controls

  • Restrict local access and enforce least privilege on affected hosts.
  • Monitor vendor guidance and exploitation sources for a material change.

Verification

  1. Confirm that the asset runs Xen XAPI and falls inside the recorded affected range.
  2. Recheck the vendor advisory before scheduling a change because no verified fixed version is currently retained.
  3. Validate exposure, authentication requirements and compensating controls in the actual environment.
  4. Reopen this reassessment when CVSS, KEV, EPSS, exploit evidence or remediation changes.
Mitigation target: Within 3 daysRemediation target: Within 90 days

This automated reassessment organises public evidence. It does not know asset exposure, business impact or control effectiveness and does not replace CVSS or a human risk decision.

Optional official sources

National CERT insights
?CERT means Computer Emergency Response Team; CSIRT is the closely related term Computer Security Incident Response Team.

Choose official national sources for this report. Each advisory shows its original language. Your selection is remembered on this device and included in shared links.

Official European source

ENISA European Vulnerability Database

Official EUVD identifiers, advisory evidence and known-exploited context. Missing fields are not treated as evidence of low risk.

1 current
ENISA EUVD identifier

EUVD-2026-42608

No EUVD known-exploited evidence

ENISA has published the identifier mapping but no EUVD description has been stored yet.

EUVD state
Present in the current official mapping
Known exploitation
Not present in the current ENISA EUVD known-exploited dataset. This is not proof of no exploitation.
ENISA score
Not supplied in the stored EUVD record
Advisory evidence
No linked advisory details stored yet
Recommended actionWithin 7 days

Critical technical severity; prioritise exposed affected systems while verifying vendor guidance.

Fix not verified
01

What, why and how

[This CNA information record relates to multiple CVEs; the text explains which aspects/vulnerabilities correspond to which CVE.] XAPI can configure different users with different roles, using Role Based Access Control. For more details, see: https://docs.xenserver.com/en-us/xencenter/current-release/rbac-overview.html#rbac-roles The pool-admin role is fully privileged. Notably, users with this role can also SSH into the host as root. The other administrator roles are pool-operator, vm-power-admin and vm-admin, each of which are authorised to configure and manage various aspects of the system. Some settings are inadequately restricted, and can be set by a lower privilege of administrator than expected. * CVE-2026-23559: A vm-admin can set VBD.other_config:backend-local and turn arbitrary files in dom0 into VDIs (virtual disks) and give said disks to a VM they control. This is an arbitrary read and/or modify of files in dom0. * CVE-2026-23560: A vm-admin can set VM.other-config:is_system_domain and mark a VM as a system domain. System domains are ignored and left running during certain other host/pool operations, and may be hidden from view in tooling. * CVE-2026-23561: A vm-admin can set VM.other_config:storage_driver_domain and mark a VM as the storage domain for a particular host storage connection (PBD). Shutting down the VM can cause the PBD to be erroneously marked as unplugged when it is not. * CVE-2026-23562: Configuration of PCI passthrough is normally restricted to the pool-admin role. However one API was missing this check, allowing a vm-admin access to unintended host hardware. * CVE-2026-42486: A vm-admin can set the VM.platform:hvm_serial parameter, which should be restricted to the pool-admin role, as it can allow arbitrary dom0 file write.

What

[This CNA information record relates to multiple CVEs; the text explains which aspects/vulnerabilities correspond to which CVE.] XAPI can configure different users with different roles, using Role Based Access Control. For more details, see: https://docs.xenserver.com/en-us/xencenter/current-release/rbac-overview.html#rbac-roles The pool-admin role is fully privileged. Notably, users with this role can also SSH into the host as root. The other administrator roles are pool-operator, vm-power-admin and vm-admin, each of which are authorised to configure and manage various aspects of the system. Some settings are inadequately restricted, and can be set by a lower privilege of administrator than expected. * CVE-2026-23559: A vm-admin can set VBD.other_config:backend-local and turn arbitrary files in dom0 into VDIs (virtual disks) and give said disks to a VM they control. This is an arbitrary read and/or modify of files in dom0. * CVE-2026-23560: A vm-admin can set VM.other-config:is_system_domain and mark a VM as a system domain. System domains are ignored and left running during certain other host/pool operations, and may be hidden from view in tooling. * CVE-2026-23561: A vm-admin can set VM.other_config:storage_driver_domain and mark a VM as the storage domain for a particular host storage connection (PBD). Shutting down the VM can cause the PBD to be erroneously marked as unplugged when it is not. * CVE-2026-23562: Configuration of PCI passthrough is normally restricted to the pool-admin role. However one API was missing this check, allowing a vm-admin access to unintended host hardware. * CVE-2026-42486: A vm-admin can set the VM.platform:hvm_serial parameter, which should be restricted to the pool-admin role, as it can allow arbitrary dom0 file write.

Why

The product performs an operation at a privilege level that is higher than the minimum level required, which creates new weaknesses or amplifies the consequences of other weaknesses.

How

An attacker operating through local access may attempt exploitation without authentication or user interaction. If successful, the issue may cause the confidentiality, integrity or availability impact described by the vendor.

What

[This CNA information record relates to multiple CVEs; the text explains which aspects/vulnerabilities correspond to which CVE.] XAPI can configure different users with different roles, using Role Based Access Control. For more details, see: https://docs.xenserver.com/en-us/xencenter/current-release/rbac-overview.html#rbac-roles The pool-admin role is fully privileged. Notably, users with this role can also SSH into the host as root. The other administrator roles are pool-operator, vm-power-admin and vm-admin, each of which are authorised to configure and manage various aspects of the system. Some settings are inadequately restricted, and can be set by a lower privilege of administrator than expected. * CVE-2026-23559: A vm-admin can set VBD.other_config:backend-local and turn arbitrary files in dom0 into VDIs (virtual disks) and give said disks to a VM they control. This is an arbitrary read and/or modify of files in dom0. * CVE-2026-23560: A vm-admin can set VM.other-config:is_system_domain and mark a VM as a system domain. System domains are ignored and left running during certain other host/pool operations, and may be hidden from view in tooling. * CVE-2026-23561: A vm-admin can set VM.other_config:storage_driver_domain and mark a VM as the storage domain for a particular host storage connection (PBD). Shutting down the VM can cause the PBD to be erroneously marked as unplugged when it is not. * CVE-2026-23562: Configuration of PCI passthrough is normally restricted to the pool-admin role. However one API was missing this check, allowing a vm-admin access to unintended host hardware. * CVE-2026-42486: A vm-admin can set the VM.platform:hvm_serial parameter, which should be restricted to the pool-admin role, as it can allow arbitrary dom0 file write.

Why

The product performs an operation at a privilege level that is higher than the minimum level required, which creates new weaknesses or amplifies the consequences of other weaknesses.

How

An attacker operating through local access may attempt exploitation without authentication or user interaction. If successful, the issue may cause the confidentiality, integrity or availability impact described by the vendor.

02

Exploit reality and attack path

CVSS severity, EPSS forecast probability, public exploit material and CISA-confirmed exploitation are separate signals.

Observed exploitation
?Confirmed exploitation and public exploit material are separate signals. Attacks can occur without public proof-of-concept or exploit code.
No confirmed evidence

No CISA KEV match was present at the last successful refresh. This means no confirmation from that source, not proof of no exploitation.

Public PoC / exploit material
?Confirmed exploitation and public exploit material are separate signals. Attacks can occur without public proof-of-concept or exploit code.
None recorded

No exploit-tagged reference or CISA SSVC proof-of-concept state is currently recorded. Research may still exist outside the structured feeds.

Likely attack path
local access → Execution with Unnecessary Privileges → cause the confidentiality, integrity or availability impact described by the vendor
Attack surface
Local
Privileges required
None: unauthenticated exploitation is possible
User interaction
None
Attack complexity
Low: no specialised conditions are recorded
Security boundary
Not a CVSS 4.0 base metric
Weakness
?CWE means Common Weakness Enumeration: a standard category for the underlying weakness.
CWE-250 ↗

CWE-250: Execution with Unnecessary Privileges. The product performs an operation at a privilege level that is higher than the minimum level required, which creates new weaknesses or amplifies the consequences of other weaknesses.

CVSS vector
?CVSS means Common Vulnerability Scoring System. The vector records the metric values used to calculate technical severity.
CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H

Common Vulnerability Scoring System 4.0: the compact vector below is decoded into plain language.

AVLocalAttack vector: The attacker needs local access to the vulnerable system.ACLowAttack complexity: No specialised conditions are required beyond attacker-controlled input.ATNoneAttack requirements: No additional deployment or execution condition is required.PRNonePrivileges required: The attacker does not need an account or existing privileges.UINoneUser interaction: No action by another user is required.VCHighVulnerable-system confidentiality: A successful attack can cause a major loss.VIHighVulnerable-system integrity: A successful attack can cause a major loss.VAHighVulnerable-system availability: A successful attack can cause a major loss.SCHighSubsequent-system confidentiality: A successful attack can cause a major loss.SIHighSubsequent-system integrity: A successful attack can cause a major loss.SAHighSubsequent-system availability: A successful attack can cause a major loss.
Post-exploitation / living off the land
The issue can support a local privilege or sandbox boundary transition; normal system utilities may then be available in the gained context.
UnauthenticatedCWE-250
A

Official authority intelligence

Only matched European and national findings are included. Language selectors and unavailable sources are omitted.

BSI · German · WID-SEC-2026-1306Xen und Citrix Systems XenServer: Mehrere Schwachstellen

Ein Angreifer kann mehrere Schwachstellen in Xen und Citrix Systems XenServer ausnutzen, um seine Privilegien zu erhöhen, Sicherheitsmaßnahmen zu umgehen, Daten zu verändern und offenzulegen oder einen Denial-of-Service-Zustand zu verursachen.

Official advisory ↗
CERT-FR · French · CERTFR-2026-AVI-0509Multiples vulnérabilités dans Xen

De multiples vulnérabilités ont été découvertes dans Xen. Certaines d'entre elles permettent à un attaquant de provoquer une élévation de privilèges, un déni de service à distance et une atteinte à la confidentialité des données.

Official advisory ↗
03

Patch and workaround

Operational remediation based on structured source evidence.

Status
?Patch availability is based on structured fixed-version fields and authoritative update references. If no fix is verified, check the vendor advisory before making a change.
Fix not verified
Affected
XAPI: all
Fixed
No fixed version is explicitly recorded in the structured CVE data.
Action
No verified patch reference is present in the current structured sources. Check the vendor advisory before making a change.
Workaround
No verified workaround is recorded. Limit untrusted access and use least privilege until authoritative guidance is available.
04

Evidence and provenance

Published 9 Jul 2026 · Last source change 10 Jul 2026, 03:55 UTC · CWE-250 · Execution with Unnecessary Privileges

CVE recordCVE.org · 5.2
CVSS sourceCNA
EPSS source
?The date BlackTree first stored a score for this CVE from the daily FIRST EPSS feed.
FIRST · tracked since 2026-08-14
European sourceENISA EUVD · EUVD-2026-42608
Product sourceCNA
Remediation sourceCVE/CNA references
CWE sourceCNA
NVD statusNVD not scheduled

Core structured fields are present and their contributing authorities are shown above.

Material change intelligence

What changed after publication

View recent updates ↗

No material field changes have been recorded since change tracking began. Routine source refreshes and cosmetic edits are intentionally excluded.

Material fields only · duplicate refreshes suppressed · history retained for the configured operational retention period
Technical terms and abbreviations used in this report
CVE
Common Vulnerabilities and Exposures: the public identifier for one disclosed vulnerability.
CVSS
Common Vulnerability Scoring System: a technical severity framework; it is not patching priority by itself.
EPSS
Exploit Prediction Scoring System: FIRST's estimate of the probability that exploitation activity will be observed in the next 30 days; it is a forecast, not confirmation.
CWE
Common Weakness Enumeration: the standard category describing the underlying software or hardware weakness.
CNA
CVE Numbering Authority: an organisation authorised to assign and publish CVE records.
CISA ADP
Cybersecurity and Infrastructure Security Agency Authorized Data Publisher: structured enrichment added to a CVE record.
NVD
National Vulnerability Database: NIST's enrichment service for CVE records.
CERT / CSIRT
A computer security incident response team that publishes warnings or coordinates incident response.
PoC
Proof of concept: public material that demonstrates or helps reproduce exploitation.
CSAF
Common Security Advisory Framework: a machine-readable format for security advisories.
LoTL
Living off the land: abuse of legitimate tools or system functions during an attack.
Free version - for non-commercial use only.CVE-2026-42486 · cve.blacktree.nl