Evidence used
- No CISA KEV confirmation is currently recorded.
- EPSS is 0.20% for the current model date.
BlackTreeCVE IntelligenceAMD · Kintex™ 7-Series FPGA
High technical severity; prioritise exposed affected systems while verifying vendor guidance.
High technical severity; prioritise exposed affected systems while verifying vendor guidance.
Fix not verifiedImproper Protection Against Voltage and Clock Glitches in FPGA devices, could allow an attacker with physical access to undervolt the platform resulting in a loss of confidentiality.
Improper Protection Against Voltage and Clock Glitches in FPGA devices, could allow an attacker with physical access to undervolt the platform resulting in a loss of confidentiality.
The device does not contain or contains incorrectly implemented circuitry or sensors to detect and mitigate voltage and clock glitches and protect sensitive information or software contained on the device.
An attacker operating through physical access may attempt exploitation without authentication or user interaction. If successful, the issue may cause the confidentiality, integrity or availability impact described by the vendor.
Improper Protection Against Voltage and Clock Glitches in FPGA devices, could allow an attacker with physical access to undervolt the platform resulting in a loss of confidentiality.
The device does not contain or contains incorrectly implemented circuitry or sensors to detect and mitigate voltage and clock glitches and protect sensitive information or software contained on the device.
An attacker operating through physical access may attempt exploitation without authentication or user interaction. If successful, the issue may cause the confidentiality, integrity or availability impact described by the vendor.
CVSS severity, EPSS forecast probability, public exploit material and CISA-confirmed exploitation are separate signals.
No CISA KEV match was present at the last successful refresh. This means no confirmation from that source, not proof of no exploitation.
No exploit-tagged reference or CISA SSVC proof-of-concept state is currently recorded. Research may still exist outside the structured feeds.
CWE-1247: Improper Protection Against Voltage and Clock Glitches. The device does not contain or contains incorrectly implemented circuitry or sensors to detect and mitigate voltage and clock glitches and protect sensitive information or software contained on the device.
CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:HCommon Vulnerability Scoring System 4.0: the compact vector below is decoded into plain language.
Operational remediation based on structured source evidence.
Published 24 Sept 2025 · Last source change 25 Sept 2025, 13:48 UTC · CWE-1247 · Improper Protection Against Voltage and Clock Glitches
Core structured fields are present and their contributing authorities are shown above.
No material field changes have been recorded since change tracking began. Routine source refreshes and cosmetic edits are intentionally excluded.