BlackTreeIndependent security intelligence
← Back to the CVE catalogue
Full vulnerability report · 2025
CVE-2025-47809High confidence

Wibu CodeMeter before 8.30a sometimes allows privilege escalation immediately after installation (before a logoff or reboot)

Wibu · CodeMeter

8.2HighCVSS 3.1
Recommended action
Within 7 days

High technical severity; prioritise exposed affected systems while verifying vendor guidance.

Patch available
Direct vendor intelligence

Authoritative vendor CSAF and VEX advisories

Structured product status and remediation from the issuing vendor. Product-state explanations are always visible; large lists can be searched or downloaded.

3 current
SSA-331739 · CSAF 2.0 · revision 3 · interimSiemens ProductCERTSSA-331739: Privilege Escalation Vulnerability in WIBU CodeMeter Runtime Affecting Siemens Products
4 known affected

The vendor explicitly identifies these products as affected by this CVE.

  • SIMATIC PDM Maintenance Station V5.0 < V5.0.2
  • SIMATIC WinCC OA V3.18 < V3.18.032
  • SIMATIC WinCC OA V3.19 < V3.19.020
  • SIMATIC WinCC OA V3.20 < V3.20.008
Summary
Wibu CodeMeter before 8.30a sometimes allows privilege escalation immediately after installation (before a logoff or reboot). For exploitation, there must have been an unprivileged installation with UAC, and the CodeMeter Control Center component must be installed, and the CodeMeter Control Center component must not have been restarted. In this scenario, the local user can navigate from Import License to a privileged instance of Windows Explorer.
Remediation
Update to V3.18 P032 or later version
SSA-201595 · CSAF 2.0 · revision 4 · interimSiemens ProductCERTSSA-201595: Privilege Escalation Vulnerability in WIBU CodeMeter Runtime Affecting the Desigo CC Product Family and SENTRON Powermanager
9 known affected

The vendor explicitly identifies these products as affected by this CVE.

  • Desigo CC family V5.0
  • Desigo CC family V5.1
  • Desigo CC family V6
  • Desigo CC family V7
  • Desigo CC family V8
  • SENTRON Powermanager V5
  • SENTRON Powermanager V6
  • SENTRON Powermanager V7
  • SENTRON Powermanager V8
Summary
Wibu CodeMeter before 8.30a sometimes allows privilege escalation immediately after installation (before a logoff or reboot). For exploitation, there must have been an unprivileged installation with UAC, and the CodeMeter Control Center component must be installed, and the CodeMeter Control Center component must not have been restarted. In this scenario, the local user can navigate from Import License to a privileged instance of Windows Explorer.
Remediation
Update to V8.0 QU2 or later version
SCA-2025-0014 · CSAF 2.0 · revision 1 · finalSICK PSIRTCodeMeter vulnerablity affects SICK CODE-LOC and SICK LIDAR-LOC
2 known affected

The vendor explicitly identifies these products as affected by this CVE.

  • SICK CODE-LOC with Firmware < LLS-2.8.1.24092R
  • SICK LIDAR-LOC with Firmware < LLS-2.8.1.24092R
Summary
Wibu CodeMeter before 8.30a sometimes allows privilege escalation immediately after installation (before a logoff or reboot). For exploitation, there must have been an unprivileged installation with UAC, and the CodeMeter Control Center component must be installed, and the CodeMeter Control Center component must not have been restarted. In this scenario, the local user can navigate from Import License to a privileged instance of Windows Explorer.
Remediation
On Microsoft Windows systems, it is strongly recommended to upgrade to the latest version (LLS-2.8.1.24092R).
Optional official sources

National CERT insights
?CERT means Computer Emergency Response Team; CSIRT is the closely related term Computer Security Incident Response Team.

Select the national-authority views to include. The exact source language is shown on each matched advisory. Your choice is remembered on this device and encoded in the shareable URL.

Official European source

ENISA European Vulnerability Database

Official EUVD identifiers, advisory evidence and known-exploited context. Missing fields are not treated as evidence of low risk.

1 current
ENISA EUVD identifier

EUVD-2025-15399

No EUVD known-exploited evidence

Wibu CodeMeter before 8.30a sometimes allows privilege escalation immediately after installation (before a logoff or reboot). For exploitation, there must have been an unprivileged installation with UAC, and the CodeMeter Control Center component must be installed, and the CodeMeter Control Center component must not have been restarted. In this scenario, the local user can navigate from Import License to a privileged instance of Windows Explorer.

EUVD state
Present in the current official mapping
Known exploitation
Not present in the current ENISA EUVD known-exploited dataset. This is not proof of no exploitation.
ENISA score
8.2 · CVSS 3.1
Advisory evidence
No linked advisory details stored yet
Recommended actionWithin 7 days

High technical severity; prioritise exposed affected systems while verifying vendor guidance.

Patch available
01

What, why and how

Wibu CodeMeter before 8.30a sometimes allows privilege escalation immediately after installation (before a logoff or reboot). For exploitation, there must have been an unprivileged installation with UAC, and the CodeMeter Control Center component must be installed, and the CodeMeter Control Center component must not have been restarted. In this scenario, the local user can navigate from Import License to a privileged instance of Windows Explorer.

What

Wibu CodeMeter before 8.30a sometimes allows privilege escalation immediately after installation (before a logoff or reboot). For exploitation, there must have been an unprivileged installation with UAC, and the CodeMeter Control Center component must be installed, and the CodeMeter Control Center component must not have been restarted. In this scenario, the local user can navigate from Import License to a privileged instance of Windows Explorer.

Why

The elevated privilege level required to perform operations such as chroot() should be dropped immediately after the operation is performed.

How

An attacker operating through local access may attempt exploitation with elevated privileges. If successful, the issue may gain additional privileges.

What

Wibu CodeMeter before 8.30a sometimes allows privilege escalation immediately after installation (before a logoff or reboot). For exploitation, there must have been an unprivileged installation with UAC, and the CodeMeter Control Center component must be installed, and the CodeMeter Control Center component must not have been restarted. In this scenario, the local user can navigate from Import License to a privileged instance of Windows Explorer.

Why

The elevated privilege level required to perform operations such as chroot() should be dropped immediately after the operation is performed.

How

An attacker operating through local access may attempt exploitation with elevated privileges. If successful, the issue may gain additional privileges.

02

Exploit reality and attack path

CVSS severity, EPSS forecast probability, public exploit material and CISA-confirmed exploitation are separate signals.

Observed exploitation
?Confirmed exploitation and public exploit material are separate signals. Attacks can occur without public proof-of-concept or exploit code.
No confirmed evidence

No CISA KEV match was present at the last successful refresh. This means no confirmation from that source, not proof of no exploitation.

Public PoC / exploit material
?Confirmed exploitation and public exploit material are separate signals. Attacks can occur without public proof-of-concept or exploit code.
None recorded

No exploit-tagged reference or CISA SSVC proof-of-concept state is currently recorded. Research may still exist outside the structured feeds.

Likely attack path
local access → Least Privilege Violation → gain additional privileges
Attack surface
Local
Privileges required
High: elevated access is required
User interaction
None
Attack complexity
Low: no specialised conditions are recorded
Security boundary
Changed: exploitation can affect a different security authority
Weakness
?CWE means Common Weakness Enumeration: a standard category for the underlying weakness.
CWE-272

CWE-272: Least Privilege Violation. The elevated privilege level required to perform operations such as chroot() should be dropped immediately after the operation is performed.

CVSS vector
?CVSS means Common Vulnerability Scoring System. The vector records the metric values used to calculate technical severity.
CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H

Common Vulnerability Scoring System 3.1: the compact vector below is decoded into plain language.

AVLocalAttack vector: The attacker needs local access to the vulnerable system.ACLowAttack complexity: No specialised conditions are required beyond attacker-controlled input.PRHighPrivileges required: The attacker needs elevated or administrative privileges.UINoneUser interaction: No action by another user is required.SChangedScope: The attack can affect a component governed by a different security authority.CHighConfidentiality impact: A successful attack can cause a major loss.IHighIntegrity impact: A successful attack can cause a major loss.AHighAvailability impact: A successful attack can cause a major loss.
Post-exploitation / living off the land
The issue can support a local privilege or sandbox boundary transition; normal system utilities may then be available in the gained context.
Privilege escalationCWE-272
A

Official authority intelligence

Only matched European and national findings are included. Language selectors and unavailable sources are omitted.

ENISA EUVD · EUVD-2025-15399Official EUVD mapping

Wibu CodeMeter before 8.30a sometimes allows privilege escalation immediately after installation (before a logoff or reboot). For exploitation, there must have been an unprivileged installation with UAC, and the CodeMeter Control Center component must be installed, and the CodeMeter Control Center component must not have been restarted. In this scenario, the local user can navigate from Import License to a privileged instance of Windows Explorer.

Official EUVD record
BSI · German · WID-SEC-W-2025-1076Wibu-Systems CodeMeter: Schwachstelle ermöglicht Privilegieneskalation

Ein lokaler Angreifer kann eine Schwachstelle in Wibu-Systems CodeMeter ausnutzen, um seine Privilegien zu erhöhen.

Official advisory
CERT-FR · French · CERTFR-2025-AVI-0704Vulnérabilité dans les produits Siemens

Une vulnérabilité a été découverte dans les produits Siemens. Elle permet à un attaquant de provoquer une élévation de privilèges.

Official advisory
CERT-FR · French · CERTFR-2025-AVI-0677Multiples vulnérabilités dans les produits Siemens

orrectif de sécurité pour la vulnérabilité CVE-2025-30033. SIMATIC Control Function Library (CFL) toutes versions pour la vulnérabilité CVE-2025-30033 SIMATIC D7-SYS toutes versions pour la vulnérabilité CVE-2025-30033 SIMATIC eaSie Core Package (6DL5424-0AX00-0AV8) toutes versions pour la vulnérabilité CVE-2025-30033 SIMATIC eaSie PCS 7 Skill Package (6DL5424-0BX00-0AV8) toutes versions pour la vulnérabilité CVE-2025-30033 SIMATIC eaSie Workflow Skills toutes versions pour la vulnérabilité CVE-2025-30033 SIMATIC Energy Suite toutes versions pour la vulnérabilité CVE-2025-30033 SIMATIC Information Server toutes versions pour la vulnérabilité CVE-2025-47809 SIMATIC Logon V1.6 toutes versions. L'éditeur indique que le produit ne bénéficiera pas de correctif de sécurité pour la vulnérabilité CVE-2025-30033. SIMATIC Logon V2.0 toutes versions pour la vulnérabilité CVE-2025-30033 SIMATIC Management Agent toutes versions pour la vulnérabilité CVE-2025-30033 SIMATIC Management Console toutes versions pour la vulnérabilité CVE-2025-30033 SIMATIC MTP CREATOR V2.x et V3.x toutes versions. L'éditeur indique que le produit ne bénéficiera pas de correctif de sécurité pour la vulnérabilité CVE-2025-30033. SIMATIC MTP Integrator toutes versions pour la vulnérabilité CVE-2025-30033 SIMATIC NET PC Software tou

Official advisory
NCSC-NL · Dutch · NCSC-2026-0346Kwetsbaarheden verholpen in Siemens producten

Wibu CodeMeter versions prior to 8.30a contain a privilege escalation vulnerability occurring immediately after installation when installed without elevated privileges, enabling local users to access a privileged Windows Explorer instance via the CodeMeter Control Center before restart.

Official advisory
NCSC-NL · Dutch · NCSC-2025-0246Kwetsbaarheden verholpen in Siemens producten

De kwetsbaarheden stellen een kwaadwillende mogelijk in staat aanvallen uit te voeren die kunnen leiden tot de volgende categorieën schade: * Denial-of-Service (DoS) * Cross-Site Scripting * Manipulatie van gegevens * Omzeilen van een beveiligingsmaatregel * (Remote) code execution (SYSTEM rechten) * (Remote) code execution (Gebruikersrechten) * Toegang tot gevoelige gegevens * Verhogen van rechten De kwaadwillende heeft hiervoor toegang nodig tot de productieomgeving. Het is goed gebruik een dergelijke omgeving niet publiek toegankelijk te hebben.

Official advisory
03

Patch and workaround

Operational remediation based on structured source evidence.

Status
?Patch availability is based on structured fixed-version fields and authoritative update references. If no fix is verified, check the vendor advisory before making a change.
Patch available
Affected
SIMATIC PDM Maintenance Station V5.0 < V5.0.2; SIMATIC WinCC OA V3.18 < V3.18.032; SIMATIC WinCC OA V3.19 < V3.19.020; SIMATIC WinCC OA V3.20 < V3.20.008
Fixed
No fixed version is explicitly recorded in the structured CVE data.
Action
Update to V3.18 P032 or later version
Workaround
No verified workaround is recorded. Limit untrusted access and use least privilege until authoritative guidance is available.
04

Evidence and provenance

Published 16 May 2025 · Last source change 8 Sept 2026, 08:42 UTC · CWE-272 · Least Privilege Violation

CVE recordCVE.org · 5.2
CVSS sourceCNA
EPSS source
?The date BlackTree first stored a score for this CVE from the daily FIRST EPSS feed.
FIRST · tracked since 2026-08-14
European sourceENISA EUVD · EUVD-2025-15399
Product sourceVendor CSAF · Siemens ProductCERT
Remediation sourceVendor CSAF · Siemens ProductCERT
CWE sourceCNA
NVD statusNVD not scheduled

Core structured fields are present and their contributing authorities are shown above.

Material change intelligence

What changed after publication

View recent updates →
  1. Affected versionsThe structured affected or fixed version information changed.
    Before
    SIMATIC PDM Maintenance Station V5.0; SIMATIC WinCC OA V3.18; SIMATIC WinCC OA V3.19; SIMATIC WinCC OA V3.20
    After
    SIMATIC PDM Maintenance Station V5.0 < V5.0.2; SIMATIC WinCC OA V3.18 < V3.18.032; SIMATIC WinCC OA V3.19 < V3.19.020; SIMATIC WinCC OA V3.20 < V3.20.008
    Siemens ProductCERT
  2. Vendor guidanceAuthoritative vendor guidance changed from authoritative remediation link to authoritative remediation link.
    Before
    authoritative remediation link
    After
    authoritative remediation link
    SICK PSIRT
Material fields only · duplicate refreshes suppressed · history retained for the configured operational retention period
Technical terms and abbreviations used in this report
CVE
Common Vulnerabilities and Exposures: the public identifier for one disclosed vulnerability.
CVSS
Common Vulnerability Scoring System: a technical severity framework; it is not patching priority by itself.
EPSS
Exploit Prediction Scoring System: FIRST's estimate of the probability that exploitation activity will be observed in the next 30 days; it is a forecast, not confirmation.
CWE
Common Weakness Enumeration: the standard category describing the underlying software or hardware weakness.
CNA
CVE Numbering Authority: an organisation authorised to assign and publish CVE records.
CISA ADP
Cybersecurity and Infrastructure Security Agency Authorized Data Publisher: structured enrichment added to a CVE record.
NVD
National Vulnerability Database: NIST's enrichment service for CVE records.
CERT / CSIRT
A computer security incident response team that publishes warnings or coordinates incident response.
PoC
Proof of concept: public material that demonstrates or helps reproduce exploitation.
CSAF
Common Security Advisory Framework: a machine-readable format for security advisories.
LoTL
Living off the land: abuse of legitimate tools or system functions during an attack.
Free version - for non-commercial use only.CVE-2025-47809 · cve.blacktree.nl