A vulnerability has been identified in SINEC Security Monitor (All versions < V4.10.0)

Siemens · SINEC Security Monitor

Official source article: Siemens SSA-882673 ↗. Check the applicable product and release in the original source.

8.4HighCVSS 4.0
Recommended action
Patch only the product branches with a verified fix

High technical severity; prioritise exposed affected systems while verifying vendor guidance. Verified remediation exists for at least one product or source, but 1 structured product or package state remain unresolved. Apply remediation only to the exact product branch confirmed by its source.

Fix availability varies by product
R
Operational reassessment

Published severity in operational context

Open reassessment dashboard →
Published severityHighOperational priority:Medium, lowered one band.downgradedsince 9 Dec 2025

Evidence used

  • No CISA KEV confirmation is currently recorded.
  • Exploitation requires an existing local or physical foothold with privileges.
  • EPSS is 0.16% for the current model date.

Compensating controls

  • Validate the affected product branch and deploy the verified fixed release.
  • Restrict local access and enforce least privilege on affected hosts.
  • Monitor vendor guidance and exploitation sources for a material change.

Verification

  1. Confirm that the asset runs Siemens SINEC Security Monitor and falls inside the recorded affected range.
  2. Verify the installed build against the product-specific fixed version after deployment.
  3. Validate exposure, authentication requirements and compensating controls in the actual environment.
  4. Reopen this reassessment when CVSS, KEV, EPSS, exploit evidence or remediation changes.
Mitigation target: As exposure requiresRemediation target: Within 365 days

This automated reassessment organises public evidence. It does not know asset exposure, business impact or control effectiveness and does not replace CVSS or a human risk decision.

Cross-source reconciliation

Remediation availability differs by product scope

Verified remediation exists for at least one product or source, but 1 structured product or package state remain unresolved. Apply remediation only to the exact product branch confirmed by its source.

Direct vendor intelligence

Authoritative vendor CSAF and VEX advisories

Structured product status and remediation from the issuing vendor. Product-state explanations are always visible; large lists can be searched or downloaded.

1 current
SSA-882673 · CSAF 2.0 · revision 1 · interimSiemens ProductCERTSSA-882673: Multiple Vulnerabilities in SINEC Security Monitor before V4.10.0
1 known affected

The vendor explicitly identifies these products as affected by this CVE.

  • SINEC Security Monitor
Summary
The affected application does not have proper authorization checks for the file_transfer feature in ssmctl-client command. This could allow an authenticated, lowly privileged local attacker to read or write to any file on server or sensor.
Remediation
Update to V4.10.0 or later version
Optional official sources

National CERT insights
?CERT means Computer Emergency Response Team; CSIRT is the closely related term Computer Security Incident Response Team.

Choose official national sources for this report. Each advisory shows its original language. Your selection is remembered on this device and included in shared links.

Official European source

ENISA European Vulnerability Database

Official EUVD identifiers, advisory evidence and known-exploited context. Missing fields are not treated as evidence of low risk.

1 current
ENISA EUVD identifier

EUVD-2025-201922

No EUVD known-exploited evidence

ENISA has published the identifier mapping but no EUVD description has been stored yet.

EUVD state
Present in the current official mapping
Known exploitation
Not present in the current ENISA EUVD known-exploited dataset. This is not proof of no exploitation.
ENISA score
Not supplied in the stored EUVD record
Advisory evidence
No linked advisory details stored yet
Recommended actionPatch only the product branches with a verified fix

High technical severity; prioritise exposed affected systems while verifying vendor guidance. Verified remediation exists for at least one product or source, but 1 structured product or package state remain unresolved. Apply remediation only to the exact product branch confirmed by its source.

Fix availability varies by product
01

What, why and how

A vulnerability has been identified in SINEC Security Monitor (All versions < V4.10.0). The affected application does not have proper authorization checks for the file_transfer feature in ssmctl-client command. This could allow an authenticated, lowly privileged local attacker to read or write to any file on server or sensor.

What

A vulnerability has been identified in SINEC Security Monitor (All versions < V4.10.0). The affected application does not have proper authorization checks for the file_transfer feature in ssmctl-client command. This could allow an authenticated, lowly privileged local attacker to read or write to any file on server or sensor.

Why

The product does not perform or incorrectly performs an authorization check when an actor attempts to access a resource or perform an action.

How

An attacker operating through local access may attempt exploitation with elevated privileges. If successful, the issue may cause the confidentiality, integrity or availability impact described by the vendor.

What

A vulnerability has been identified in SINEC Security Monitor (All versions < V4.10.0). The affected application does not have proper authorization checks for the file_transfer feature in ssmctl-client command. This could allow an authenticated, lowly privileged local attacker to read or write to any file on server or sensor.

Why

The product does not perform or incorrectly performs an authorization check when an actor attempts to access a resource or perform an action.

How

An attacker operating through local access may attempt exploitation with elevated privileges. If successful, the issue may cause the confidentiality, integrity or availability impact described by the vendor.

02

Exploit reality and attack path

CVSS severity, EPSS forecast probability, public exploit material and CISA-confirmed exploitation are separate signals.

Observed exploitation
?Confirmed exploitation and public exploit material are separate signals. Attacks can occur without public proof-of-concept or exploit code.
No confirmed evidence

No CISA KEV match was present at the last successful refresh. This means no confirmation from that source, not proof of no exploitation.

Public PoC / exploit material
?Confirmed exploitation and public exploit material are separate signals. Attacks can occur without public proof-of-concept or exploit code.
None recorded

No exploit-tagged reference or CISA SSVC proof-of-concept state is currently recorded. Research may still exist outside the structured feeds.

Likely attack path
local access → Improper Authorization → cause the confidentiality, integrity or availability impact described by the vendor
Attack surface
Local
Privileges required
High: elevated access is required
User interaction
None
Attack complexity
Low: no specialised conditions are recorded
Security boundary
Not a CVSS 4.0 base metric
Weakness
?CWE means Common Weakness Enumeration: a standard category for the underlying weakness.
CWE-285 ↗

CWE-285: Improper Authorization. The product does not perform or incorrectly performs an authorization check when an actor attempts to access a resource or perform an action.

CVSS vector
?CVSS means Common Vulnerability Scoring System. The vector records the metric values used to calculate technical severity.
CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Common Vulnerability Scoring System 4.0: the compact vector below is decoded into plain language.

AVLocalAttack vector: The attacker needs local access to the vulnerable system.ACLowAttack complexity: No specialised conditions are required beyond attacker-controlled input.ATNoneAttack requirements: No additional deployment or execution condition is required.PRHighPrivileges required: The attacker needs elevated or administrative privileges.UINoneUser interaction: No action by another user is required.VCHighVulnerable-system confidentiality: A successful attack can cause a major loss.VIHighVulnerable-system integrity: A successful attack can cause a major loss.VAHighVulnerable-system availability: A successful attack can cause a major loss.SCNoneSubsequent-system confidentiality: No direct loss is represented by this metric.SINoneSubsequent-system integrity: No direct loss is represented by this metric.SANoneSubsequent-system availability: No direct loss is represented by this metric.
Post-exploitation / living off the land
The issue can support a local privilege or sandbox boundary transition; normal system utilities may then be available in the gained context.
CWE-285
A

Official authority intelligence

Only matched European and national findings are included. Language selectors and unavailable sources are omitted.

Cyber Security Agency of Singapore · English · CSA-SB-20251210Security Bulletin 10 Dec 2025

The Cyber Security Agency of Singapore included this CVE in its official Security Bulletin 10 Dec 2025, published on 10 December 2025. Open the linked bulletin for the product, severity and reference information published in that issue.

Official advisory ↗
JVN iPedia · Japanese · JVNDB-2025-021714シーメンスの sinec security monitor における認可に関する脆弱性

シーメンスの sinec security monitor には、認可に関する脆弱性が存在します。

Official advisory ↗
NCSC-NL · Dutch · NCSC-2025-0382Kwetsbaarheden verholpen in Siemens producten

A vulnerability in SINEC Security Monitor (versions < V4.10.0) allows lowly privileged authenticated local attackers to read or write any file on the server or sensor due to inadequate authorization checks.

Official advisory ↗
03

Patch and workaround

Operational remediation based on structured source evidence.

Status
?Patch availability is based on structured fixed-version fields and authoritative update references. If no fix is verified, check the vendor advisory before making a change.
Fix availability varies by product
Affected
SINEC Security Monitor
Fixed
Update to V4.10.0 or later version
Action
Use the product-specific evidence above. Patch only products with a verified fixed release, and keep every affected or under-investigation state without a matching fix in the remediation queue.
Workaround
No verified workaround is recorded. Limit untrusted access and use least privilege until authoritative guidance is available.
Official vendor articles1 stored document

Linked articles are downloaded and versioned as source evidence. A CVE mention or approved update relationship does not, by itself, verify a fix for every product branch.

  • SSA-882673 →Original publisher ↗Searchable text snapshot · Captured 29 Sep 2026Siemens Security Advisory by Siemens ProductCERT SSA-882673: Multiple Vulnerabilities in SINEC Security Monitor before V4.10.0 Publication Date: 2025-12-09 Last Update: 2025-12-09 Current Version: V1.0 CVSS v3.1 Base Score: 6.7 CVSS v4.0 Base Score: 8.4 SUMMARY SINEC Security Monitor before V4.10.0 contains mul
04

Evidence and provenance

Published 9 Dec 2025 · Last source change 9 Dec 2025, 15:45 UTC · CWE-285 · Improper Authorization

CVE recordCVE.org · 5.2
CVSS sourceCNA
EPSS source
?The date BlackTree first stored a score for this CVE from the daily FIRST EPSS feed.
FIRST · tracked since 2026-08-14
European sourceENISA EUVD · EUVD-2025-201922
Product sourceVendor CSAF · Siemens ProductCERT
Remediation sourceVendor CSAF · Siemens ProductCERT
CWE sourceCNA
NVD statusNVD enriched

Core structured fields are present and their contributing authorities are shown above.

Material change intelligence

What changed after publication

View recent updates ↗
  1. Affected versionsThe structured affected or fixed version information changed.
    Before
    < V4.10.0 · Fixed: No fixed version is explicitly recorded in the structured CVE data.
    After
    < V4.10.0 · Fixed: Update to V4.10.0 or later version
    Siemens ProductCERT ↗
  2. Remediation statusRemediation status changed from Awaiting fix to Patch available.
    Before
    Awaiting fix
    After
    Patch available
    Siemens ProductCERT ↗
Material fields only · duplicate refreshes suppressed · history retained for the configured operational retention period
Technical terms and abbreviations used in this report
CVE
Common Vulnerabilities and Exposures: the public identifier for one disclosed vulnerability.
CVSS
Common Vulnerability Scoring System: a technical severity framework; it is not patching priority by itself.
EPSS
Exploit Prediction Scoring System: FIRST's estimate of the probability that exploitation activity will be observed in the next 30 days; it is a forecast, not confirmation.
CWE
Common Weakness Enumeration: the standard category describing the underlying software or hardware weakness.
CNA
CVE Numbering Authority: an organisation authorised to assign and publish CVE records.
CISA ADP
Cybersecurity and Infrastructure Security Agency Authorized Data Publisher: structured enrichment added to a CVE record.
NVD
National Vulnerability Database: NIST's enrichment service for CVE records.
CERT / CSIRT
A computer security incident response team that publishes warnings or coordinates incident response.
PoC
Proof of concept: public material that demonstrates or helps reproduce exploitation.
CSAF
Common Security Advisory Framework: a machine-readable format for security advisories.
LoTL
Living off the land: abuse of legitimate tools or system functions during an attack.
Free version - for non-commercial use only.CVE-2025-40830 · cve.blacktree.nl