BlackTreeCVE Intelligence
← Back to the CVE catalogue
Full vulnerability report · 2026
CVE-2025-13162High confidence

Advant Master Online Builder DLL vulnerability

ABB · Control Builder A

4.1MediumCVSS 4.0
Recommended action
Scheduled

Medium technical severity with no CISA KEV confirmation; remediate through the normal risk-based patch cycle unless local exposure raises the priority.

Patch available
R
Operational reassessment

Published severity in operational context

Open reassessment dashboard →
Published severityMediumOperational priority:Low, lowered one band.downgradedsince 23 Jun 2026

Evidence used

  • No CISA KEV confirmation is currently recorded.
  • Exploitation requires an existing local or physical foothold with privileges.
  • EPSS is 0.12% for the current model date.

Compensating controls

  • Validate the affected product branch and deploy the verified fixed release.
  • Restrict local access and enforce least privilege on affected hosts.
  • Monitor vendor guidance and exploitation sources for a material change.

Verification

  1. Confirm that the asset runs ABB Control Builder A and falls inside the recorded affected range.
  2. Verify the installed build against the product-specific fixed version after deployment.
  3. Validate exposure, authentication requirements and compensating controls in the actual environment.
  4. Reopen this reassessment when CVSS, KEV, EPSS, exploit evidence or remediation changes.
Mitigation target: No default targetRemediation target: Normal maintenance

This automated reassessment organises public evidence. It does not know asset exposure, business impact or control effectiveness and does not replace CVSS or a human risk decision.

Direct vendor intelligence

Authoritative vendor CSAF and VEX advisories

Structured product status and remediation from the issuing vendor. Product-state explanations are always visible; large lists can be searched or downloaded.

1 current
7PAA020047 · CSAF 2.0 · revision 1 · finalABB Product Security Incident Response Team (PSIRT)CVE-2025-13162
5 known affected

The vendor explicitly identifies these products as affected by this CVE.

  • ABB Control Builder A <=1.4/4
  • ABB 800xA for Advant Master <=6.0.3-1
  • ABB 800xA for Advant Master <=6.1.1-1
  • ABB 800xA for Advant Master 6.1.1-3
  • ABB 800xA for Advant Master 6.2.0-1
Summary
The application improperly handles the search path for loading DLL´s, potentially allowing unauthorized libraries from untrusted directories. An attacker who obtains the necessary access could exploit the vulnerability leading to unauthorized code execution and compromising system integrity.
Remediation
ABB has investigated the vulnerability and remediated it in the newly released versions. The vulnerability has been resolved in the product versions listed as fixed in the advisory. - Version 6.1.1-2 does not contain this vulnerability and therefore no update is required. The vulnerability was again introduced in 6.1.1-3 when an older ONB version was included in the release media. - Version 6.1.1-4 do not contain this vulnerability but present version 6.1.1-3 by 800xA System Installer and System Configuration Console (SCC). Version 6.1.1-4 is therefore withdrawn. - Version 6.2.0-2 do not contain this vulnerability but present version 6.2.0-1 by 800xA System Installer and System Configuration Console (SCC). Version 6.2.0-2 is therefore withdrawn. ABB recommends that customers apply the update at their earliest convenience. - Control Builder A: It is recommended to update Control Builder A to version 1.4/5 or later. - 800xA for Advant Master: - Versions 6.0.3-1 and earlier, - Versions 6.1.1-1 and earlier, - Versions 6.1.1-2, 6.1.1-3, and 6.1.1-4 should be updated to version 6.1.1-5 or later. - 800xA for Advant Master: - Versions 6.2.0-1 and 6.2.0-2 should be updated to version 6.2.0-3 or later.
Optional official sources

National CERT insights
?CERT means Computer Emergency Response Team; CSIRT is the closely related term Computer Security Incident Response Team.

Choose official national sources for this report. Each advisory shows its original language. Your selection is remembered on this device and included in shared links.

Official European source

ENISA European Vulnerability Database

Official EUVD identifiers, advisory evidence and known-exploited context. Missing fields are not treated as evidence of low risk.

1 current
ENISA EUVD identifier

EUVD-2025-210312

No EUVD known-exploited evidence

ENISA has published the identifier mapping but no EUVD description has been stored yet.

EUVD state
Present in the current official mapping
Known exploitation
Not present in the current ENISA EUVD known-exploited dataset. This is not proof of no exploitation.
ENISA score
Not supplied in the stored EUVD record
Advisory evidence
No linked advisory details stored yet
Recommended actionScheduled

Medium technical severity with no CISA KEV confirmation; remediate through the normal risk-based patch cycle unless local exposure raises the priority.

Patch available
01

What, why and how

Uncontrolled Search Path Element vulnerability in ABB Control Builder A, ABB 800xA for Advant Master. This issue affects Control Builder A: through 1.4/4; 800xA for Advant Master: through 6.0.3-1, through 6.1.1-1, 6.1.1-3, 6.2.0-1.

What

Uncontrolled Search Path Element vulnerability in ABB Control Builder A, ABB 800xA for Advant Master. This issue affects Control Builder A: through 1.4/4; 800xA for Advant Master: through 6.0.3-1, through 6.1.1-1, 6.1.1-3, 6.2.0-1.

Why

The product uses a fixed or controlled search path to find resources, but one or more locations in that path can be under the control of unintended actors.

How

An attacker operating through local access may attempt exploitation with low privileges. If successful, the issue may cause the confidentiality, integrity or availability impact described by the vendor.

What

Uncontrolled Search Path Element vulnerability in ABB Control Builder A, ABB 800xA for Advant Master. This issue affects Control Builder A: through 1.4/4; 800xA for Advant Master: through 6.0.3-1, through 6.1.1-1, 6.1.1-3, 6.2.0-1.

Why

The product uses a fixed or controlled search path to find resources, but one or more locations in that path can be under the control of unintended actors.

How

An attacker operating through local access may attempt exploitation with low privileges. If successful, the issue may cause the confidentiality, integrity or availability impact described by the vendor.

02

Exploit reality and attack path

CVSS severity, EPSS forecast probability, public exploit material and CISA-confirmed exploitation are separate signals.

Observed exploitation
?Confirmed exploitation and public exploit material are separate signals. Attacks can occur without public proof-of-concept or exploit code.
No confirmed evidence

No CISA KEV match was present at the last successful refresh. This means no confirmation from that source, not proof of no exploitation.

Public PoC / exploit material
?Confirmed exploitation and public exploit material are separate signals. Attacks can occur without public proof-of-concept or exploit code.
None recorded

No exploit-tagged reference or CISA SSVC proof-of-concept state is currently recorded. Research may still exist outside the structured feeds.

Likely attack path
local access → Uncontrolled Search Path Element → cause the confidentiality, integrity or availability impact described by the vendor
Attack surface
Local
Privileges required
Low: a basic authenticated account is required
User interaction
Passive interaction required
Attack complexity
High: exploitation depends on specific conditions
Security boundary
Not a CVSS 4.0 base metric
Weakness
?CWE means Common Weakness Enumeration: a standard category for the underlying weakness.
CWE-427 ↗

CWE-427: Uncontrolled Search Path Element. The product uses a fixed or controlled search path to find resources, but one or more locations in that path can be under the control of unintended actors.

CVSS vector
?CVSS means Common Vulnerability Scoring System. The vector records the metric values used to calculate technical severity.
CVSS:4.0/AV:L/AC:H/AT:P/PR:L/UI:P/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N

Common Vulnerability Scoring System 4.0: the compact vector below is decoded into plain language.

AVLocalAttack vector: The attacker needs local access to the vulnerable system.ACHighAttack complexity: Successful exploitation depends on specific conditions outside the attacker's direct control.ATPresentAttack requirements: A particular deployment or execution condition must be present.PRLowPrivileges required: The attacker needs basic user-level privileges.UIPassiveUser interaction: A user must unknowingly interact with the vulnerable system.VCNoneVulnerable-system confidentiality: No direct loss is represented by this metric.VIHighVulnerable-system integrity: A successful attack can cause a major loss.VANoneVulnerable-system availability: No direct loss is represented by this metric.SCNoneSubsequent-system confidentiality: No direct loss is represented by this metric.SINoneSubsequent-system integrity: No direct loss is represented by this metric.SANoneSubsequent-system availability: No direct loss is represented by this metric.
Post-exploitation / living off the land
The issue can support a local privilege or sandbox boundary transition; normal system utilities may then be available in the gained context.
CWE-427
A

Official authority intelligence

Only matched European and national findings are included. Language selectors and unavailable sources are omitted.

Cyber Security Agency of Singapore · English · CSA-SB-20260624Security Bulletin 24 June 2026

The Cyber Security Agency of Singapore included this CVE in its official Security Bulletin 24 June 2026, published on 24 June 2026. Open the linked bulletin for the product, severity and reference information published in that issue.

Official advisory ↗
03

Patch and workaround

Operational remediation based on structured source evidence.

Status
?Patch availability is based on structured fixed-version fields and authoritative update references. If no fix is verified, check the vendor advisory before making a change.
Patch available
Affected
Fixed
Action
ABB has investigated the vulnerability and remediated it in the newly released versions. The vulnerability has been resolved in the product versions listed as fixed in the advisory. - Version 6.1.1-2 does not contain this vulnerability and therefore no update is required. The vulnerability was again introduced in 6.1.1-3 when an older ONB version was included in the release media. - Version 6.1.1-4 do not contain this vulnerability but present version 6.1.1-3 by 800xA System Installer and System Configuration Console (SCC). Version 6.1.1-4 is therefore withdrawn. - Version 6.2.0-2 do not contain this vulnerability but present version 6.2.0-1 by 800xA System Installer and System Configuration Console (SCC). Version 6.2.0-2 is therefore withdrawn. ABB recommends that customers apply the update at their earliest convenience. - Control Builder A: It is recommended to update Control Builder A to version 1.4/5 or later. - 800xA for Advant Master: - Versions 6.0.3-1 and earlier, - Versions 6.1.1-1 and earlier, - Versions 6.1.1-2, 6.1.1-3, and 6.1.1-4 should be updated to version 6.1.1-5 or later. - 800xA for Advant Master: - Versions 6.2.0-1 and 6.2.0-2 should be updated to version 6.2.0-3 or later.
Workaround
No verified workaround is recorded. Limit untrusted access and use least privilege until authoritative guidance is available.
04

Evidence and provenance

Published 23 Jun 2026 · Last source change 23 Jun 2026, 17:21 UTC · CWE-427 · Uncontrolled Search Path Element

CVE recordCVE.org · 5.2
CVSS sourceCNA
EPSS source
?The date BlackTree first stored a score for this CVE from the daily FIRST EPSS feed.
FIRST · tracked since 2026-08-14
European sourceENISA EUVD · EUVD-2025-210312
Product sourceVendor CSAF · ABB Product Security Incident Response Team (PSIRT)
Remediation sourceVendor CSAF · ABB Product Security Incident Response Team (PSIRT)
CWE sourceCNA
NVD statusNVD awaiting enrichment

Core structured fields are present and their contributing authorities are shown above.

Material change intelligence

What changed after publication

View recent updates ↗
  1. Affected versionsThe structured affected or fixed version information changed.
    Before
    Control Builder A: ≤ 1.4/4; 800xA for Advant Master: ≤ 6.0.3-1, ≤ 6.1.1-1, 6.1.1-3, 6.2.0-1 · Fixed: ABB has investigated the vulnerability and remediated it in the newly released versions. The vulnerability has been resolved in the product versions listed as fixed in the advisory. - Version 6.1.1-2 does not contain this vulnerability and therefore no update is required. The vulnerability was again introduced in 6.1.1-3 when an older ONB version was included in the release media. - Version 6.1.1-4 do not contain this vulnerability but present version 6.1.1-3 by 800xA System Installer and System Configuration Console (SCC). Version 6.1.1-4 is therefore withdrawn. - Version 6.2.0-2 do not contain this vulnerability but present version 6.2.0-1 by 800xA System Installer and System Configuration Console (SCC). Version 6.2.0-2 is therefore withdrawn. ABB recommends that customers apply the update at their earliest convenience. - Control Builder A: It is recommended to update Control Builder A to version 1.4/5 or later. - 800xA for Advant Master: - Versions 6.0.3-1 and earlier, - Versions 6.1.1-1 and earlier, - Versions 6.1.1-2, 6.1.1-3, and 6.1.1-4 should be updated to version 6.1.1-5 or later. - 800xA for Advant Master: - Versions 6.2.0-1 and 6.2.0-2 should be updated to version 6.2.0-3 or later.
    After
    Control Builder A: ≤ 1.4/4; 800xA for Advant Master: ≤ 6.0.3-1, ≤ 6.1.1-1, 6.1.1-3, 6.2.0-1 · Fixed: 800xA for Advant Master: 6.1.1-2, 6.1.1-4, 6.2.0-2
    CNA ↗
  2. Vendor guidanceAuthoritative vendor guidance changed: removed patch: search.abb.com/Download.aspx?DocumentID=7PAA020047&LanguageCode=en&DocumentPartId=&Action=Launch.
    Before
    patch: search.abb.com/Download.aspx?DocumentID=7PAA020047&LanguageCode=en&DocumentPartId=&Action=Launch · remediation: search.abb.com/Download.aspx?DocumentID=7PAA020047&LanguageCode=en&DocumentPartId=&Action=Launch
    After
    remediation: search.abb.com/Download.aspx?DocumentID=7PAA020047&LanguageCode=en&DocumentPartId=&Action=Launch
    CNA ↗
  3. Affected versionsThe structured affected or fixed version information changed.
    Before
    ≤ 1.4/4; ≤ 6.0.3-1; ≤ 6.1.1-1; 6.1.1-3; 6.2.0-1 · Fixed: ABB has investigated the vulnerability and remediated it in the newly released versions. The vulnerability has been resolved in the product versions listed as fixed in the advisory. - Version 6.1.1-2 does not contain this vulnerability and therefore no update is required. The vulnerability was again introduced in 6.1.1-3 when an older ONB version was included in the release media. - Version 6.1.1-4 do not contain this vulnerability but present version 6.1.1-3 by 800xA System Installer and System Configuration Console (SCC). Version 6.1.1-4 is therefore withdrawn. - Version 6.2.0-2 do not contain this vulnerability but present version 6.2.0-1 by 800xA System Installer and System Configuration Console (SCC). Version 6.2.0-2 is therefore withdrawn. ABB recommends that customers apply the update at their earliest convenience. - Control Builder A: It is recommended to update Control Builder A to version 1.4/5 or later. - 800xA for Advant Master: - Versions 6.0.3-1 and earlier, - Versions 6.1.1-1 and earlier, - Versions 6.1.1-2, 6.1.1-3, and 6.1.1-4 should be updated to version 6.1.1-5 or later. - 800xA for Advant Master: - Versions 6.2.0-1 and 6.2.0-2 should be updated to version 6.2.0-3 or later.
    After
    Control Builder A: ≤ 1.4/4; 800xA for Advant Master: ≤ 6.0.3-1, ≤ 6.1.1-1, 6.1.1-3, 6.2.0-1 · Fixed: 800xA for Advant Master: 6.1.1-2, 6.1.1-4, 6.2.0-2
    CNA ↗
  4. Affected versionsThe structured affected or fixed version information changed.
    Before
    Control Builder A: ≤ 1.4/4; 800xA for Advant Master: ≤ 6.0.3-1, ≤ 6.1.1-1, 6.1.1-3, 6.2.0-1 · Fixed: 800xA for Advant Master: 6.1.1-2, 6.1.1-4, 6.2.0-2
    After
    Control Builder A: ≤ 1.4/4; 800xA for Advant Master: ≤ 6.0.3-1, ≤ 6.1.1-1, 6.1.1-3, 6.2.0-1 · Fixed: ABB has investigated the vulnerability and remediated it in the newly released versions. The vulnerability has been resolved in the product versions listed as fixed in the advisory. - Version 6.1.1-2 does not contain this vulnerability and therefore no update is required. The vulnerability was again introduced in 6.1.1-3 when an older ONB version was included in the release media. - Version 6.1.1-4 do not contain this vulnerability but present version 6.1.1-3 by 800xA System Installer and System Configuration Console (SCC). Version 6.1.1-4 is therefore withdrawn. - Version 6.2.0-2 do not contain this vulnerability but present version 6.2.0-1 by 800xA System Installer and System Configuration Console (SCC). Version 6.2.0-2 is therefore withdrawn. ABB recommends that customers apply the update at their earliest convenience. - Control Builder A: It is recommended to update Control Builder A to version 1.4/5 or later. - 800xA for Advant Master: - Versions 6.0.3-1 and earlier, - Versions 6.1.1-1 and earlier, - Versions 6.1.1-2, 6.1.1-3, and 6.1.1-4 should be updated to version 6.1.1-5 or later. - 800xA for Advant Master: - Versions 6.2.0-1 and 6.2.0-2 should be updated to version 6.2.0-3 or later.
    ABB Product Security Incident Response Team (PSIRT) ↗
  5. Affected versionsThe structured affected or fixed version information changed.
    Before
    ≤ 1.4/4; ≤ 6.0.3-1; ≤ 6.1.1-1; 6.1.1-3; 6.2.0-1 · Fixed: 6.1.1-2; 6.1.1-4; 6.2.0-2
    After
    ≤ 1.4/4; ≤ 6.0.3-1; ≤ 6.1.1-1; 6.1.1-3; 6.2.0-1 · Fixed: ABB has investigated the vulnerability and remediated it in the newly released versions. The vulnerability has been resolved in the product versions listed as fixed in the advisory. - Version 6.1.1-2 does not contain this vulnerability and therefore no update is required. The vulnerability was again introduced in 6.1.1-3 when an older ONB version was included in the release media. - Version 6.1.1-4 do not contain this vulnerability but present version 6.1.1-3 by 800xA System Installer and System Configuration Console (SCC). Version 6.1.1-4 is therefore withdrawn. - Version 6.2.0-2 do not contain this vulnerability but present version 6.2.0-1 by 800xA System Installer and System Configuration Console (SCC). Version 6.2.0-2 is therefore withdrawn. ABB recommends that customers apply the update at their earliest convenience. - Control Builder A: It is recommended to update Control Builder A to version 1.4/5 or later. - 800xA for Advant Master: - Versions 6.0.3-1 and earlier, - Versions 6.1.1-1 and earlier, - Versions 6.1.1-2, 6.1.1-3, and 6.1.1-4 should be updated to version 6.1.1-5 or later. - 800xA for Advant Master: - Versions 6.2.0-1 and 6.2.0-2 should be updated to version 6.2.0-3 or later.
    ABB Product Security Incident Response Team (PSIRT) ↗
  6. Vendor guidanceAuthoritative vendor guidance changed: added remediation: search.abb.com/Download.aspx?DocumentID=7PAA020047&LanguageCode=en&DocumentPartId=&Action=Launch; removed remediation: nvd.nist.gov/CVE-2025-13162.
    Before
    remediation: nvd.nist.gov/CVE-2025-13162
    After
    remediation: search.abb.com/Download.aspx?DocumentID=7PAA020047&LanguageCode=en&DocumentPartId=&Action=Launch
    ABB Product Security Incident Response Team (PSIRT) ↗
Material fields only · duplicate refreshes suppressed · history retained for the configured operational retention period
CVE published
Fixed release or patch reference recorded
Fixed release recorded from official guidance
Technical terms and abbreviations used in this report
CVE
Common Vulnerabilities and Exposures: the public identifier for one disclosed vulnerability.
CVSS
Common Vulnerability Scoring System: a technical severity framework; it is not patching priority by itself.
EPSS
Exploit Prediction Scoring System: FIRST's estimate of the probability that exploitation activity will be observed in the next 30 days; it is a forecast, not confirmation.
CWE
Common Weakness Enumeration: the standard category describing the underlying software or hardware weakness.
CNA
CVE Numbering Authority: an organisation authorised to assign and publish CVE records.
CISA ADP
Cybersecurity and Infrastructure Security Agency Authorized Data Publisher: structured enrichment added to a CVE record.
NVD
National Vulnerability Database: NIST's enrichment service for CVE records.
CERT / CSIRT
A computer security incident response team that publishes warnings or coordinates incident response.
PoC
Proof of concept: public material that demonstrates or helps reproduce exploitation.
CSAF
Common Security Advisory Framework: a machine-readable format for security advisories.
LoTL
Living off the land: abuse of legitimate tools or system functions during an attack.
Free version - for non-commercial use only.CVE-2025-13162 · cve.blacktree.nl