BlackTreeCVE IntelligenceAdvantech · EKI-6333AC-2G
High technical severity; prioritise exposed affected systems while verifying vendor guidance.
High technical severity; prioritise exposed affected systems while verifying vendor guidance.
Patch availableA CWE-15 "External Control of System or Configuration Setting" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by authenticated users by restoring a tampered configuration backup.
A CWE-15 "External Control of System or Configuration Setting" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by authenticated users by restoring a tampered configuration backup.
One or more system settings or configuration elements can be externally controlled by a user.
An attacker operating through a network path may attempt exploitation with elevated privileges. If successful, the issue may cause the confidentiality, integrity or availability impact described by the vendor.
A CWE-15 "External Control of System or Configuration Setting" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by authenticated users by restoring a tampered configuration backup.
One or more system settings or configuration elements can be externally controlled by a user.
An attacker operating through a network path may attempt exploitation with elevated privileges. If successful, the issue may cause the confidentiality, integrity or availability impact described by the vendor.
CVSS severity, EPSS forecast probability, public exploit material and CISA-confirmed exploitation are separate signals.
No CISA KEV match was present at the last successful refresh. This means no confirmation from that source, not proof of no exploitation.
No exploit-tagged reference or CISA SSVC proof-of-concept state is currently recorded. Research may still exist outside the structured feeds.
CWE-15: External Control of System or Configuration Setting. One or more system settings or configuration elements can be externally controlled by a user.
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:HCommon Vulnerability Scoring System 3.1: the compact vector below is decoded into plain language.
Operational remediation based on structured source evidence.
Published 26 Nov 2024 · Last source change 26 Nov 2024, 14:19 UTC · CWE-15 · External Control of System or Configuration Setting