Evidence used
- No CISA KEV confirmation is currently recorded.
- The selected CVSS metric records a network-reachable, unauthenticated path with no user interaction.
- EPSS is 2.03% for the current model date.
BlackTreeCVE IntelligenceTriangle MicroWorks · SCADA Data Gateway
Critical technical impact with a remotely reachable, unauthenticated path; no CISA KEV confirmation is currently recorded.
Critical technical impact with a remotely reachable, unauthenticated path; no CISA KEV confirmation is currently recorded.
Fix not verifiedTriangle MicroWorks SCADA Data Gateway Missing Authentication Vulnerability. This vulnerability allows remote attackers to bypass authentication on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is not required to exploit this vulnerability. The specific flaw exists due to the lack of user authentication. The issue results from missing authentication in the default system configuration. An attacker can leverage this vulnerability to execute arbitrary code in the context of root. Was ZDI-CAN-20501.
Triangle MicroWorks SCADA Data Gateway Missing Authentication Vulnerability. This vulnerability allows remote attackers to bypass authentication on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is not required to exploit this vulnerability. The specific flaw exists due to the lack of user authentication. The issue results from missing authentication in the default system configuration. An attacker can leverage this vulnerability to execute arbitrary code in the context of root. Was ZDI-CAN-20501.
A security-sensitive function is reachable without the authentication check that should protect it.
An attacker operating through a network path may attempt exploitation without authentication or user interaction. If successful, the issue may execute code or commands in the affected security context.
Triangle MicroWorks SCADA Data Gateway Missing Authentication Vulnerability. This vulnerability allows remote attackers to bypass authentication on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is not required to exploit this vulnerability. The specific flaw exists due to the lack of user authentication. The issue results from missing authentication in the default system configuration. An attacker can leverage this vulnerability to execute arbitrary code in the context of root. Was ZDI-CAN-20501.
A security-sensitive function is reachable without the authentication check that should protect it.
An attacker operating through a network path may attempt exploitation without authentication or user interaction. If successful, the issue may execute code or commands in the affected security context.
CVSS severity, EPSS forecast probability, public exploit material and CISA-confirmed exploitation are separate signals.
No CISA KEV match was present at the last successful refresh. This means no confirmation from that source, not proof of no exploitation.
No exploit-tagged reference or CISA SSVC proof-of-concept state is currently recorded. Research may still exist outside the structured feeds.
CWE-306: Missing Authentication for Critical Function. The product does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources.
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:HCommon Vulnerability Scoring System 3.0: the compact vector below is decoded into plain language.
Operational remediation based on structured source evidence.
Published 3 May 2024 · Last source change 2 Aug 2024, 18:10 UTC · CWE-306 · Missing Authentication for Critical Function
Core structured fields are present and their contributing authorities are shown above.
No material field changes have been recorded since change tracking began. Routine source refreshes and cosmetic edits are intentionally excluded.