Evidence used
- No CISA KEV confirmation is currently recorded.
- EPSS is 3.90% for the current model date.
BlackTreeCVE IntelligenceAdobe · Acrobat Reader
Official source article: Adobe APSB21-104 ↗. Check the applicable product and release in the original source.
Low technical severity with no CISA KEV confirmation; remediate through the normal risk-based patch cycle unless local exposure raises the priority.
Low technical severity with no CISA KEV confirmation; remediate through the normal risk-based patch cycle unless local exposure raises the priority.
Fix not verifiedAdobe Acrobat Reader DC version 21.007.20095 (and earlier), 21.007.20096 (and earlier), 20.004.30015 (and earlier), and 17.011.30202 (and earlier) is affected by a use-after-free that allow a remote attacker to disclose sensitive information on affected installations of of Adobe Acrobat Reader DC. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of JPG2000 images.
Adobe Acrobat Reader DC version 21.007.20095 (and earlier), 21.007.20096 (and earlier), 20.004.30015 (and earlier), and 17.011.30202 (and earlier) is affected by a use-after-free that allow a remote attacker to disclose sensitive information on affected installations of of Adobe Acrobat Reader DC. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of JPG2000 images.
The program can continue using memory after it has been released, producing unsafe and attacker-influenceable behaviour.
An attacker operating through local access may attempt exploitation without authentication after a user interaction. If successful, the issue may obtain information outside the intended access boundary.
Adobe Acrobat Reader DC version 21.007.20095 (and earlier), 21.007.20096 (and earlier), 20.004.30015 (and earlier), and 17.011.30202 (and earlier) is affected by a use-after-free that allow a remote attacker to disclose sensitive information on affected installations of of Adobe Acrobat Reader DC. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of JPG2000 images.
The program can continue using memory after it has been released, producing unsafe and attacker-influenceable behaviour.
An attacker operating through local access may attempt exploitation without authentication after a user interaction. If successful, the issue may obtain information outside the intended access boundary.
CVSS severity, EPSS forecast probability, public exploit material and CISA-confirmed exploitation are separate signals.
No CISA KEV match was present at the last successful refresh. This means no confirmation from that source, not proof of no exploitation.
No exploit-tagged reference or CISA SSVC proof-of-concept state is currently recorded. Research may still exist outside the structured feeds.
CWE-416: Use After Free. The product reuses or references memory after it has been freed. At some point afterward, the memory may be allocated again and saved in another pointer, while the original pointer references a location somewhere within the new allocation. Any operations using the original pointer are no longer valid because the memory belongs to the code that operates on the new pointer.
CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:NCommon Vulnerability Scoring System 3.0: the compact vector below is decoded into plain language.
Operational remediation based on structured source evidence.
Published 15 Oct 2021 · Last source change 23 Apr 2025, 19:25 UTC · CWE-416 · Use After Free
Core structured fields are present and their contributing authorities are shown above.
No material field changes have been recorded since change tracking began. Routine source refreshes and cosmetic edits are intentionally excluded.