Evidence used
- No CISA KEV confirmation is currently recorded.
- A structured source references public exploit or proof-of-concept material.
- EPSS is 1.64% for the current model date.
BlackTreeCVE IntelligenceFidelis Cybersecurity · Fidelis Network
Critical technical impact and a public exploit reference; no CISA KEV confirmation is currently recorded.
Critical technical impact and a public exploit reference; no CISA KEV confirmation is currently recorded.
Patch availableVulnerability in the CommandPost, Collector, and Sensor components of Fidelis Network and Deception enables an attacker with user level access to the CLI to inject root level commands into the component and neighboring Fidelis components. The vulnerability is present in Fidelis Network and Deception versions prior to 9.3.7 and in version 9.4. Patches and updates are available to address this vulnerability.
Vulnerability in the CommandPost, Collector, and Sensor components of Fidelis Network and Deception enables an attacker with user level access to the CLI to inject root level commands into the component and neighboring Fidelis components. The vulnerability is present in Fidelis Network and Deception versions prior to 9.3.7 and in version 9.4. Patches and updates are available to address this vulnerability.
Untrusted input is incorporated into an operating-system command without safe parameter handling.
An attacker operating through a network path may attempt exploitation with low privileges. If successful, the issue may cause the confidentiality, integrity or availability impact described by the vendor.
Vulnerability in the CommandPost, Collector, and Sensor components of Fidelis Network and Deception enables an attacker with user level access to the CLI to inject root level commands into the component and neighboring Fidelis components. The vulnerability is present in Fidelis Network and Deception versions prior to 9.3.7 and in version 9.4. Patches and updates are available to address this vulnerability.
Untrusted input is incorporated into an operating-system command without safe parameter handling.
An attacker operating through a network path may attempt exploitation with low privileges. If successful, the issue may cause the confidentiality, integrity or availability impact described by the vendor.
CVSS severity, EPSS forecast probability, public exploit material and CISA-confirmed exploitation are separate signals.
No CISA KEV match was present at the last successful refresh. This means no confirmation from that source, not proof of no exploitation.
A structured CVE source labels at least one public reference as exploit material. BlackTree has not independently validated that it is safe, reliable or weaponised.
CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection'). The product constructs all or part of an OS command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended OS command when it is sent to a downstream component.
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:HCommon Vulnerability Scoring System 3.1: the compact vector below is decoded into plain language.
Operational remediation based on structured source evidence.
Published 25 Jun 2021 · Last source change 16 Sept 2024, 20:41 UTC · CWE-78 · Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Core structured fields are present and their contributing authorities are shown above.
No material field changes have been recorded since change tracking began. Routine source refreshes and cosmetic edits are intentionally excluded.