Evidence used
- No CISA KEV confirmation is currently recorded.
- The selected CVSS metric records a network-reachable, unauthenticated path with no user interaction.
- EPSS is 20.16% for the current model date.
BlackTreeCVE IntelligenceUnknown · Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)
Critical technical impact with a remotely reachable, unauthenticated path; no CISA KEV confirmation is currently recorded.
Structured product status and remediation from the issuing vendor. Product-state explanations are always visible; large lists can be searched or downloaded.
The vendor explicitly identifies these products as affected by this CVE.
Critical technical impact with a remotely reachable, unauthenticated path; no CISA KEV confirmation is currently recorded.
Patch availableA CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in remote code execution due to missing length check on user supplied data, when a constructed message is received on the network. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in remote code execution due to missing length check on user supplied data, when a constructed message is received on the network. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)
The product copies an input buffer to an output buffer without verifying that the size of the input buffer is less than the size of the output buffer.
An attacker operating through a network path may attempt exploitation without authentication or user interaction. If successful, the issue may execute code or commands in the affected security context.
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in remote code execution due to missing length check on user supplied data, when a constructed message is received on the network. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)
The product copies an input buffer to an output buffer without verifying that the size of the input buffer is less than the size of the output buffer.
An attacker operating through a network path may attempt exploitation without authentication or user interaction. If successful, the issue may execute code or commands in the affected security context.
CVSS severity, EPSS forecast probability, public exploit material and CISA-confirmed exploitation are separate signals.
No CISA KEV match was present at the last successful refresh. This means no confirmation from that source, not proof of no exploitation.
No exploit-tagged reference or CISA SSVC proof-of-concept state is currently recorded. Research may still exist outside the structured feeds.
CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow'). The product copies an input buffer to an output buffer without verifying that the size of the input buffer is less than the size of the output buffer.
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:HCommon Vulnerability Scoring System 3.1: the compact vector below is decoded into plain language.
Operational remediation based on structured source evidence.
Published 11 Feb 2022 · Last source change 3 Aug 2024, 18:51 UTC · CWE-120 · Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Missing structured fields: affected product. Missing data is not evidence of low risk; review the primary advisory.