Full vulnerability report · 2021
CVE-2021-22780High confidence

n/a EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions — Insufficiently Protected Credentials

Unknown · EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions

7.1HighCVSS 3.1
Recommended action
Patch only the product branches with a verified fix

High technical severity; prioritise exposed affected systems while verifying vendor guidance. Verified remediation exists for at least one product or source, but 3 structured product or package states remain unresolved. Apply remediation only to the exact product branch confirmed by its source.

Fix availability varies by product
R
Operational reassessment

Published severity in operational context

Open reassessment dashboard →
Published severityHighOperational priority:Medium, lowered one band.downgradedsince 3 Aug 2024

Evidence used

  • No CISA KEV confirmation is currently recorded.
  • Exploitation requires an existing local or physical foothold with privileges.
  • EPSS is 0.22% for the current model date.

Compensating controls

  • Validate the affected product branch and deploy the verified fixed release.
  • Restrict local access and enforce least privilege on affected hosts.
  • Monitor vendor guidance and exploitation sources for a material change.

Verification

  1. Confirm that the asset runs Unknown EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions and falls inside the recorded affected range.
  2. Verify the installed build against the product-specific fixed version after deployment.
  3. Validate exposure, authentication requirements and compensating controls in the actual environment.
  4. Reopen this reassessment when CVSS, KEV, EPSS, exploit evidence or remediation changes.
Mitigation target: As exposure requiresRemediation target: Within 365 days

This automated reassessment organises public evidence. It does not know asset exposure, business impact or control effectiveness and does not replace CVSS or a human risk decision.

Cross-source reconciliation

Remediation availability differs by product scope

Verified remediation exists for at least one product or source, but 3 structured product or package states remain unresolved. Apply remediation only to the exact product branch confirmed by its source.

Direct vendor intelligence

Authoritative vendor CSAF and VEX advisories

Structured product status and remediation from the issuing vendor. Product-state explanations are always visible; large lists can be searched or downloaded.

1 current
SEVD-2021-194-01 · CSAF 2.0 · revision 9.0.0 · finalSchneider Electric CPCERTEcoStruxureTM Control Expert, EcoStruxureTM Process Expert, SCADAPack RemoteConnect™ x70, and Modicon Controllers M580 and M340
3 known affected

The vendor explicitly identifies these products as affected by this CVE.

  • Schneider Electric EcoStruxure™ Control Expert versions prior to 15.0 SP1
  • Schneider Electric EcoStruxure™ Process Expert versions prior to 2021
  • Schneider Electric SCADAPack RemoteConnect™ for x70 versions prior to R2.7.3
Summary
A CWE-522: Insufficiently Protected Credentials vulnerability exists that could cause unauthorized access to a project file protected by a password when this file is shared with untrusted sources. An attacker may bypass the password protection and be able to view and modify a project file.
Remediation
EcoStruxure™ Control Expert V15.1*, available for download below, includes a fix for CVE-2021-22778, CVE-2021-22780, CVE-2021-22781, CVE-2021-22782, CVE-2020-12525: https://www.se.com/ww/en/download/document/EcoStruxureControlExpert_V15.1/ *Upgrading to EcoStruxure™ Control Expert V15.1 is the first step in a two stepsprocess to fully address CVE-2021-22779. To fully address this issue a firmwarerelease will follow. Important Note: •The fix is provided through the additional feature “file encryption”, forfurther information on the feature and how to set it up please refers to thechapter “file encryption” of the help file available in the EcoStruxure™Control Expert v15.0 SP1. •This feature is proposed by default when creating a new project. •This feature is also available, after selecting “project” in structural view, inthe “Edit/ Properties/ Project & Controller Protection” menu. •For new projects: oCustomers are recommended to apply this feature to all newprojects. •For existing projects: oCustomers are recommended to apply this feature to the existingprojects coming from trusted source. For .sta project files, as areminder, project modification can be done in connected mode toprevent desynchronization and keep the controller in RUN state. •It is possible to set a security level specific to the Derived Function Blocks(DFB) in addition to the file encryption feature. Please refer to the chapter"How to protect a DFB type" in the EcoStruxure™ Control Expert help filefor further information. •Customers are recommended to share project files only when configuredwith the encryption feature described above. If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit. These mitigations also reduce the risk of exploit for CVE-2021-22779 on all versions of EcoStruxure™ Control Expert, including V15.1: •Store the project files in a secure storage and restrict the access to onlytrusted users •When exchanging files over the network, use secure communicationprotocols •Encrypt project files when stored •Only open project files received from trusted source •Compute a hash of the project files and regularly check the consistency ofthis hash to verify the integrity before usage. •Harden the workstation running EcoStruxure™ Control Expert or Unity Pro Customers using Unity Pro should strongly consider migrating to EcoStruxure™ Control Expert. Please contact your local Schneider Electric technical support for more information.
Optional official sources

National CERT insights
?CERT means Computer Emergency Response Team; CSIRT is the closely related term Computer Security Incident Response Team.

Choose official national sources for this report. Each advisory shows its original language. Your selection is remembered on this device and included in shared links.

Official European source

ENISA European Vulnerability Database

Official EUVD identifiers, advisory evidence and known-exploited context. Missing fields are not treated as evidence of low risk.

1 current
ENISA EUVD identifier

EUVD-2021-9915

No EUVD known-exploited evidence

ENISA has published the identifier mapping but no EUVD description has been stored yet.

EUVD state
Present in the current official mapping
Known exploitation
Not present in the current ENISA EUVD known-exploited dataset. This is not proof of no exploitation.
ENISA score
Not supplied in the stored EUVD record
Advisory evidence
No linked advisory details stored yet
Recommended actionPatch only the product branches with a verified fix

High technical severity; prioritise exposed affected systems while verifying vendor guidance. Verified remediation exists for at least one product or source, but 3 structured product or package states remain unresolved. Apply remediation only to the exact product branch confirmed by its source.

Fix availability varies by product
01

What, why and how

Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause unauthorized access to a project file protected by a password when this file is shared with untrusted sources. An attacker may bypass the password protection and be able to view and modify a project file.

What

Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause unauthorized access to a project file protected by a password when this file is shared with untrusted sources. An attacker may bypass the password protection and be able to view and modify a project file.

Why

The product transmits or stores authentication credentials, but it uses an insecure method that is susceptible to unauthorized interception and/or retrieval.

How

An attacker operating through local access may attempt exploitation with low privileges. If successful, the issue may cause the confidentiality, integrity or availability impact described by the vendor.

What

Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause unauthorized access to a project file protected by a password when this file is shared with untrusted sources. An attacker may bypass the password protection and be able to view and modify a project file.

Why

The product transmits or stores authentication credentials, but it uses an insecure method that is susceptible to unauthorized interception and/or retrieval.

How

An attacker operating through local access may attempt exploitation with low privileges. If successful, the issue may cause the confidentiality, integrity or availability impact described by the vendor.

02

Exploit reality and attack path

CVSS severity, EPSS forecast probability, public exploit material and CISA-confirmed exploitation are separate signals.

Observed exploitation
?Confirmed exploitation and public exploit material are separate signals. Attacks can occur without public proof-of-concept or exploit code.
No confirmed evidence

No CISA KEV match was present at the last successful refresh. This means no confirmation from that source, not proof of no exploitation.

Public PoC / exploit material
?Confirmed exploitation and public exploit material are separate signals. Attacks can occur without public proof-of-concept or exploit code.
None recorded

No exploit-tagged reference or CISA SSVC proof-of-concept state is currently recorded. Research may still exist outside the structured feeds.

Likely attack path
local access → Insufficiently Protected Credentials → cause the confidentiality, integrity or availability impact described by the vendor
Attack surface
Local
Privileges required
Low: a basic authenticated account is required
User interaction
None
Attack complexity
Low: no specialised conditions are recorded
Security boundary
Unchanged: impact remains within the vulnerable component's security authority
Weakness
?CWE means Common Weakness Enumeration: a standard category for the underlying weakness.
CWE-522 ↗

CWE-522: Insufficiently Protected Credentials. The product transmits or stores authentication credentials, but it uses an insecure method that is susceptible to unauthorized interception and/or retrieval.

CVSS vector
?CVSS means Common Vulnerability Scoring System. The vector records the metric values used to calculate technical severity.
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N

Common Vulnerability Scoring System 3.1: the compact vector below is decoded into plain language.

AVLocalAttack vector: The attacker needs local access to the vulnerable system.ACLowAttack complexity: No specialised conditions are required beyond attacker-controlled input.PRLowPrivileges required: The attacker needs basic user-level privileges.UINoneUser interaction: No action by another user is required.SUnchangedScope: The security impact remains within the vulnerable component's authority.CHighConfidentiality impact: A successful attack can cause a major loss.IHighIntegrity impact: A successful attack can cause a major loss.ANoneAvailability impact: No direct loss is represented by this metric.
Post-exploitation / living off the land
Stolen credentials, tokens and legitimate administration functions may provide continued access without deploying a large custom toolset.
CWE-522
A

Official authority intelligence

Only matched European and national findings are included. Language selectors and unavailable sources are omitted.

Cyber Security Agency of Singapore · English · CSA-SB-20210721Security Bulletin 21 Jul 2021

The Cyber Security Agency of Singapore included this CVE in its official Security Bulletin 21 Jul 2021, published on 21 July 2021. Open the linked bulletin for the product, severity and reference information published in that issue.

Official advisory ↗
CERT-FR · French · CERTFR-2022-AVI-717Multiples vulnérabilités dans les produits Schneider

VERecord?id=CVE-2019-6843 Référence CVE CVE-2019-6844 https://www.cve.org/CVERecord?id=CVE-2019-6844 Référence CVE CVE-2019-6846 https://www.cve.org/CVERecord?id=CVE-2019-6846 Référence CVE CVE-2019-6847 https://www.cve.org/CVERecord?id=CVE-2019-6847 Référence CVE CVE-2020-12525 https://www.cve.org/CVERecord?id=CVE-2020-12525 Référence CVE CVE-2020-28895 https://www.cve.org/CVERecord?id=CVE-2020-28895 Référence CVE CVE-2020-35198 https://www.cve.org/CVERecord?id=CVE-2020-35198 Référence CVE CVE-2021-22778 https://www.cve.org/CVERecord?id=CVE-2021-22778 Référence CVE CVE-2021-22779 https://www.cve.org/CVERecord?id=CVE-2021-22779 Référence CVE CVE-2021-22780 https://www.cve.org/CVERecord?id=CVE-2021-22780 Référence CVE CVE-2021-22781 https://www.cve.org/CVERecord?id=CVE-2021-22781 Référence CVE CVE-2021-22782 https://www.cve.org/CVERecord?id=CVE-2021-22782 Référence CVE CVE-2021-22786 https://www.cve.org/CVERecord?id=CVE-2021-22786 Référence CVE CVE-2021-22789 https://www.cve.org/CVERecord?id=CVE-2021-22789 Référence CVE CVE-2021-22790 https://www.cve.org/CVERecord?id=CVE-2021-22790 Référence CVE CVE-2021-22791 https://www.cve.org/CVERecord?id=CVE-2021-22791 Référence CVE CVE-2021-22792 https://www.cve.org/CVERecord?id=CVE-2021-22792 Référence CVE CVE-2021-4104 https://www.cve.org/CVERecord?id=C

Official advisory ↗
CERT-FR · French · CERTFR-2022-AVI-628Multiples vulnérabilités dans les produits Schneider Electric

d?id=CVE-2021-21863 Référence CVE CVE-2021-21864 https://www.cve.org/CVERecord?id=CVE-2021-21864 Référence CVE CVE-2021-21865 https://www.cve.org/CVERecord?id=CVE-2021-21865 Référence CVE CVE-2021-21866 https://www.cve.org/CVERecord?id=CVE-2021-21866 Référence CVE CVE-2021-21867 https://www.cve.org/CVERecord?id=CVE-2021-21867 Référence CVE CVE-2021-21868 https://www.cve.org/CVERecord?id=CVE-2021-21868 Référence CVE CVE-2021-21869 https://www.cve.org/CVERecord?id=CVE-2021-21869 Référence CVE CVE-2021-22778 https://www.cve.org/CVERecord?id=CVE-2021-22778 Référence CVE CVE-2021-22779 https://www.cve.org/CVERecord?id=CVE-2021-22779 Référence CVE CVE-2021-22780 https://www.cve.org/CVERecord?id=CVE-2021-22780 Référence CVE CVE-2021-22781 https://www.cve.org/CVERecord?id=CVE-2021-22781 Référence CVE CVE-2021-22782 https://www.cve.org/CVERecord?id=CVE-2021-22782 Référence CVE CVE-2021-22797 https://www.cve.org/CVERecord?id=CVE-2021-22797 Référence CVE CVE-2021-29240 https://www.cve.org/CVERecord?id=CVE-2021-29240 Référence CVE CVE-2021-29241 https://www.cve.org/CVERecord?id=CVE-2021-29241 Référence CVE CVE-2021-33485 https://www.cve.org/CVERecord?id=CVE-2021-33485 Référence CVE CVE-2022-0715 https://www.cve.org/CVERecord?id=CVE-2022-0715 Référence CVE CVE-2022-22805 https://www.cve.org/CVERecord?id=CV

Official advisory ↗
CERT-FR · French · CERTFR-2022-AVI-215Multiples vulnérabilités dans les produits Schneider

a vulnérabilité CVE-2022-0715 et une correction des vulnérabilités CVE-2022-22805 et CVE-2022-22806 Smart-UPS séries SMC micrologiciels versions antérieures à UPS 04.3 permettant une correction partielle de la vulnérabilité CVE-2022-0715 et une correction des vulnérabilités CVE-2022-22805 et CVE-2022-22806 Aucun correctif n'est disponible pour les séries Smart-UPS SCL, SMX et SRT ainsi que les séries SmartConnect SMTL, SCL, et SMX. Se référer aux mesures de contournement proposées par l'éditeur Ritto Wiser Door toutes versions, se référer aux mesures de contournement proposées par l'éditeur Pour les vulnérabilités identifiées CVE-2021-22778, CVE-2021-22780, CVE-2021-22781, CVE-2021-22782 et CVE-2020-12525, la mise à niveau vers EcoStruxure Control Expert v15.1 et EcoStruxure Process Expert v2021 constitue une première étape de contournement. L'éditeur annoncera la publication d'un nouveau micrologiciel afin de corriger ces vulnérabilités. Résumé De multiples vulnérabilités ont été découvertes dans les produits Schneider. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité. Solution Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (

Official advisory ↗
CERT-FR · French · CERTFR-2021-AVI-517Multiples vulnérabilités dans les produits Schneider

d?id=CVE-2021-22769 Référence CVE CVE-2021-22770 https://www.cve.org/CVERecord?id=CVE-2021-22770 Référence CVE CVE-2021-22771 https://www.cve.org/CVERecord?id=CVE-2021-22771 Référence CVE CVE-2021-22772 https://www.cve.org/CVERecord?id=CVE-2021-22772 Référence CVE CVE-2021-22773 https://www.cve.org/CVERecord?id=CVE-2021-22773 Référence CVE CVE-2021-22774 https://www.cve.org/CVERecord?id=CVE-2021-22774 Référence CVE CVE-2021-22777 https://www.cve.org/CVERecord?id=CVE-2021-22777 Référence CVE CVE-2021-22778 https://www.cve.org/CVERecord?id=CVE-2021-22778 Référence CVE CVE-2021-22779 https://www.cve.org/CVERecord?id=CVE-2021-22779 Référence CVE CVE-2021-22780 https://www.cve.org/CVERecord?id=CVE-2021-22780 Référence CVE CVE-2021-22781 https://www.cve.org/CVERecord?id=CVE-2021-22781 Référence CVE CVE-2021-22782 https://www.cve.org/CVERecord?id=CVE-2021-22782 Référence CVE CVE-2021-22784 https://www.cve.org/CVERecord?id=CVE-2021-22784 Gestion détaillée du document le 13 juillet 2021 Version initiale Alertes Avis Bulletins d’actualités Mentions légales Conditions générales À propos Contact cyber.gouv.fr service-public.fr legifrance.gouv.fr info.gouv.fr france.fr info.gouv.fr/risques Premier Ministre / Secrétariat Général de la Défense et de la Sécurité Nationale / Agence nationale de la sécurité des

Official advisory ↗
JVN iPedia · Japanese · JVNDB-2021-009772複数の Schneider Electric 製品における認証情報の不十分な保護に関する脆弱性

EcoStruxure Control Expert、EcoStruxure Process Expert、SCADAPack RemoteConnect には、認証情報の不十分な保護に関する脆弱性が存在します。

Official advisory ↗
03

Patch and workaround

Operational remediation based on structured source evidence.

Status
?Patch availability is based on structured fixed-version fields and authoritative update references. If no fix is verified, check the vendor advisory before making a change.
Fix availability varies by product
Affected
Fixed
No fixed version is explicitly recorded in the structured CVE data.
Action
Use the product-specific evidence above. Patch only products with a verified fixed release, and keep every affected or under-investigation state without a matching fix in the remediation queue.
Workaround
No verified workaround is recorded. Limit untrusted access and use least privilege until authoritative guidance is available.
04

Evidence and provenance

Published 14 Jul 2021 · Last source change 3 Aug 2024, 18:51 UTC · CWE-522 · Insufficiently Protected Credentials

CVE recordCVE.org · 5.1
CVSS sourceNIST NVD
EPSS source
?The date BlackTree first stored a score for this CVE from the daily FIRST EPSS feed.
FIRST · tracked since 2026-08-14
European sourceENISA EUVD · EUVD-2021-9915
Product sourceVendor CSAF · Schneider Electric CPCERT
Remediation sourceVendor CSAF · Schneider Electric CPCERT
CWE sourceCNA
NVD statusNVD modified after enrichment

Missing structured fields: affected product. Missing data is not evidence of low risk; review the primary advisory.

Material change intelligence

What changed after publication

View recent updates ↗
  1. Remediation statusRemediation status changed from Awaiting fix to Mitigation available.
    Before
    Awaiting fix
    After
    Mitigation available
    Schneider Electric CPCERT ↗
Material fields only · duplicate refreshes suppressed · history retained for the configured operational retention period
Technical terms and abbreviations used in this report
CVE
Common Vulnerabilities and Exposures: the public identifier for one disclosed vulnerability.
CVSS
Common Vulnerability Scoring System: a technical severity framework; it is not patching priority by itself.
EPSS
Exploit Prediction Scoring System: FIRST's estimate of the probability that exploitation activity will be observed in the next 30 days; it is a forecast, not confirmation.
CWE
Common Weakness Enumeration: the standard category describing the underlying software or hardware weakness.
CNA
CVE Numbering Authority: an organisation authorised to assign and publish CVE records.
CISA ADP
Cybersecurity and Infrastructure Security Agency Authorized Data Publisher: structured enrichment added to a CVE record.
NVD
National Vulnerability Database: NIST's enrichment service for CVE records.
CERT / CSIRT
A computer security incident response team that publishes warnings or coordinates incident response.
PoC
Proof of concept: public material that demonstrates or helps reproduce exploitation.
CSAF
Common Security Advisory Framework: a machine-readable format for security advisories.
LoTL
Living off the land: abuse of legitimate tools or system functions during an attack.
Free version - for non-commercial use only.CVE-2021-22780 · cve.blacktree.nl