Fix not verifiedThere exists an unauthenticated BLE Interface in Sloan SmartFaucets including Optima EAF, Optima ETF/EBF, BASYS EFX, and Flushometers including SOLIS. The vulnerability allows for unauthenticated kinetic effects and information disclosure on the faucets. It is possible to use the Bluetooth Low Energy (BLE) connectivity to read and write to many BLE characteristics on the device. Some of these control the flow of water, the sensitivity of the sensors, and information about maintenance.
There exists an unauthenticated BLE Interface in Sloan SmartFaucets including Optima EAF, Optima ETF/EBF, BASYS EFX, and Flushometers including SOLIS. The vulnerability allows for unauthenticated kinetic effects and information disclosure on the faucets. It is possible to use the Bluetooth Low Energy (BLE) connectivity to read and write to many BLE characteristics on the device. Some of these control the flow of water, the sensitivity of the sensors, and information about maintenance.
A security-sensitive function is reachable without the authentication check that should protect it.
An attacker operating through the affected interface may attempt exploitation without authentication or user interaction. If successful, the issue may obtain information outside the intended access boundary.
There exists an unauthenticated BLE Interface in Sloan SmartFaucets including Optima EAF, Optima ETF/EBF, BASYS EFX, and Flushometers including SOLIS. The vulnerability allows for unauthenticated kinetic effects and information disclosure on the faucets. It is possible to use the Bluetooth Low Energy (BLE) connectivity to read and write to many BLE characteristics on the device. Some of these control the flow of water, the sensitivity of the sensors, and information about maintenance.
A security-sensitive function is reachable without the authentication check that should protect it.
An attacker operating through the affected interface may attempt exploitation without authentication or user interaction. If successful, the issue may obtain information outside the intended access boundary.
CVSS severity, EPSS forecast probability, public exploit material and CISA-confirmed exploitation are separate signals.
No CISA KEV match was present at the last successful refresh. This means no confirmation from that source, not proof of no exploitation.
A structured CVE source labels at least one public reference as exploit material. BlackTree has not independently validated that it is safe, reliable or weaponised.
CWE-306: Missing Authentication for Critical Function. The product does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources.
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:NCommon Vulnerability Scoring System 3.1: the compact vector below is decoded into plain language.
Operational remediation based on structured source evidence.
Published 30 Jun 2021 · Last source change 3 Aug 2024, 17:30 UTC · CWE-306 · Missing Authentication for Critical Function
Missing structured fields: affected product. Missing data is not evidence of low risk; review the primary advisory.
No material field changes have been recorded since change tracking began. Routine source refreshes and cosmetic edits are intentionally excluded.