Evidence used
- No CISA KEV confirmation is currently recorded.
- EPSS is 0.80% for the current model date.
BlackTreeCVE IntelligenceMedtronic · Smart Model 25000 Patient Reader
High technical severity; prioritise exposed affected systems while verifying vendor guidance.
High technical severity; prioritise exposed affected systems while verifying vendor guidance.
Patch availableMedtronic MyCareLink Smart 25000 contains an authentication protocol vulnerability where the method used to authenticate between the MCL Smart Patient Reader and the Medtronic MyCareLink Smart mobile app is vulnerable to bypass. This vulnerability enables an attacker to use another mobile device or malicious application on the patient’s smartphone to authenticate to the patient’s Medtronic Smart Reader, fooling the device into believing it is communicating with the original Medtronic smart phone application when executed within range of Bluetooth communication.
Medtronic MyCareLink Smart 25000 contains an authentication protocol vulnerability where the method used to authenticate between the MCL Smart Patient Reader and the Medtronic MyCareLink Smart mobile app is vulnerable to bypass. This vulnerability enables an attacker to use another mobile device or malicious application on the patient’s smartphone to authenticate to the patient’s Medtronic Smart Reader, fooling the device into believing it is communicating with the original Medtronic smart phone application when executed within range of Bluetooth communication.
The affected component does not establish the requesting party's identity reliably before granting access.
An attacker operating through an adjacent network may attempt exploitation without authentication after a user interaction. If successful, the issue may cause the confidentiality, integrity or availability impact described by the vendor.
Medtronic MyCareLink Smart 25000 contains an authentication protocol vulnerability where the method used to authenticate between the MCL Smart Patient Reader and the Medtronic MyCareLink Smart mobile app is vulnerable to bypass. This vulnerability enables an attacker to use another mobile device or malicious application on the patient’s smartphone to authenticate to the patient’s Medtronic Smart Reader, fooling the device into believing it is communicating with the original Medtronic smart phone application when executed within range of Bluetooth communication.
The affected component does not establish the requesting party's identity reliably before granting access.
An attacker operating through an adjacent network may attempt exploitation without authentication after a user interaction. If successful, the issue may cause the confidentiality, integrity or availability impact described by the vendor.
CVSS severity, EPSS forecast probability, public exploit material and CISA-confirmed exploitation are separate signals.
No CISA KEV match was present at the last successful refresh. This means no confirmation from that source, not proof of no exploitation.
No exploit-tagged reference or CISA SSVC proof-of-concept state is currently recorded. Research may still exist outside the structured feeds.
CWE-287: Improper Authentication. When an actor claims to have a given identity, the product does not prove or insufficiently proves that the claim is correct.
CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:HCommon Vulnerability Scoring System 3.1: the compact vector below is decoded into plain language.
Operational remediation based on structured source evidence.
Published 14 Dec 2020 · Last source change 22 May 2025, 19:34 UTC · CWE-287 · Improper Authentication
Core structured fields are present and their contributing authorities are shown above.
No material field changes have been recorded since change tracking began. Routine source refreshes and cosmetic edits are intentionally excluded.