Evidence used
- No CISA KEV confirmation is currently recorded.
- The selected CVSS metric records a network-reachable, unauthenticated path with no user interaction.
- EPSS is 5.22% for the current model date.
BlackTreeCVE IntelligenceSiemens · SIMATIC HMI Comfort Panels (incl. SIPLUS variants)
Critical technical impact with a remotely reachable, unauthenticated path; no CISA KEV confirmation is currently recorded. Verified remediation exists for at least one product or source, but 8 structured product or package states remain unresolved. Apply remediation only to the exact product branch confirmed by its source.
Verified remediation exists for at least one product or source, but 8 structured product or package states remain unresolved. Apply remediation only to the exact product branch confirmed by its source.
Structured product status and remediation from the issuing vendor. Product-state explanations are always visible; large lists can be searched or downloaded.
The vendor explicitly identifies these products as affected by this CVE.
Critical technical impact with a remotely reachable, unauthenticated path; no CISA KEV confirmation is currently recorded. Verified remediation exists for at least one product or source, but 8 structured product or package states remain unresolved. Apply remediation only to the exact product branch confirmed by its source.
Fix availability varies by productA vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions < V16 Update 3a), SIMATIC HMI KTP Mobile Panels (All versions < V16 Update 3a), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). Affected devices with enabled telnet service do not require authentication for this service. This could allow a remote attacker to gain full access to the device. (ZDI-CAN-12046)
A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions < V16 Update 3a), SIMATIC HMI KTP Mobile Panels (All versions < V16 Update 3a), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). Affected devices with enabled telnet service do not require authentication for this service. This could allow a remote attacker to gain full access to the device. (ZDI-CAN-12046)
A security-sensitive function is reachable without the authentication check that should protect it.
An attacker operating through a network path may attempt exploitation without authentication or user interaction. If successful, the issue may cause the confidentiality, integrity or availability impact described by the vendor.
A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions < V16 Update 3a), SIMATIC HMI KTP Mobile Panels (All versions < V16 Update 3a), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). Affected devices with enabled telnet service do not require authentication for this service. This could allow a remote attacker to gain full access to the device. (ZDI-CAN-12046)
A security-sensitive function is reachable without the authentication check that should protect it.
An attacker operating through a network path may attempt exploitation without authentication or user interaction. If successful, the issue may cause the confidentiality, integrity or availability impact described by the vendor.
CVSS severity, EPSS forecast probability, public exploit material and CISA-confirmed exploitation are separate signals.
No CISA KEV match was present at the last successful refresh. This means no confirmation from that source, not proof of no exploitation.
No exploit-tagged reference or CISA SSVC proof-of-concept state is currently recorded. Research may still exist outside the structured feeds.
CWE-306: Missing Authentication for Critical Function. The product does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources.
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:HCommon Vulnerability Scoring System 3.1: the compact vector below is decoded into plain language.
Operational remediation based on structured source evidence.
Published 9 Feb 2021 · Last source change 2 Jun 2026, 18:59 UTC · CWE-306 · Missing Authentication for Critical Function
Core structured fields are present and their contributing authorities are shown above.
No material field changes have been recorded since change tracking began. Routine source refreshes and cosmetic edits are intentionally excluded.