BlackTreeCVE IntelligenceUnknown · Baxter Sigma Spectrum Infusion Pumps
Low technical severity with no CISA KEV confirmation; remediate through the normal risk-based patch cycle unless local exposure raises the priority.
Low technical severity with no CISA KEV confirmation; remediate through the normal risk-based patch cycle unless local exposure raises the priority.
Fix not verifiedBaxter Sigma Spectrum Infusion Pumps Sigma Spectrum Infusion System v's6.x model 35700BAX & Baxter Spectrum Infusion System v's8.x model 35700BAX2 contain hardcoded passwords when physically entered on the keypad provide access to biomedical menus including device settings, view calibration values, network configuration of Sigma Spectrum WBM if installed.
Baxter Sigma Spectrum Infusion Pumps Sigma Spectrum Infusion System v's6.x model 35700BAX & Baxter Spectrum Infusion System v's8.x model 35700BAX2 contain hardcoded passwords when physically entered on the keypad provide access to biomedical menus including device settings, view calibration values, network configuration of Sigma Spectrum WBM if installed.
The product contains a hard-coded password, which it uses for its own inbound authentication or for outbound communication to external components.
An attacker operating through physical access may attempt exploitation without authentication or user interaction. If successful, the issue may cause the confidentiality, integrity or availability impact described by the vendor.
Baxter Sigma Spectrum Infusion Pumps Sigma Spectrum Infusion System v's6.x model 35700BAX & Baxter Spectrum Infusion System v's8.x model 35700BAX2 contain hardcoded passwords when physically entered on the keypad provide access to biomedical menus including device settings, view calibration values, network configuration of Sigma Spectrum WBM if installed.
The product contains a hard-coded password, which it uses for its own inbound authentication or for outbound communication to external components.
An attacker operating through physical access may attempt exploitation without authentication or user interaction. If successful, the issue may cause the confidentiality, integrity or availability impact described by the vendor.
CVSS severity, EPSS forecast probability, public exploit material and CISA-confirmed exploitation are separate signals.
No CISA KEV match was present at the last successful refresh. This means no confirmation from that source, not proof of no exploitation.
No exploit-tagged reference or CISA SSVC proof-of-concept state is currently recorded. Research may still exist outside the structured feeds.
CWE-259: Use of Hard-coded Password. The product contains a hard-coded password, which it uses for its own inbound authentication or for outbound communication to external components.
CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:NCommon Vulnerability Scoring System 3.1: the compact vector below is decoded into plain language.
Operational remediation based on structured source evidence.
Published 29 Jun 2020 · Last source change 4 Aug 2024, 11:48 UTC · CWE-259 · Use of Hard-coded Password
Missing structured fields: affected product. Missing data is not evidence of low risk; review the primary advisory.
No material field changes have been recorded since change tracking began. Routine source refreshes and cosmetic edits are intentionally excluded.