BlackTreeCVE Intelligence
← Back to the CVE catalogue
Full vulnerability report · 2019
CVE-2019-6540High confidence

Medtronic Conexus Radio Frequency Telemetry Protocol Cleartext Transmission of Sensitive Information

Medtronic · Conexus Radio Frequency Telemetry Protocol

6.5MediumCVSS 3.1
Recommended action
Scheduled

Medium technical severity with no CISA KEV confirmation; remediate through the normal risk-based patch cycle unless local exposure raises the priority.

Patch available
Optional official sources

National CERT insights
?CERT means Computer Emergency Response Team; CSIRT is the closely related term Computer Security Incident Response Team.

Select the national-authority views to include. The exact source language is shown on each matched advisory. Your choice is remembered on this device and encoded in the shareable URL.

Official European source

ENISA European Vulnerability Database

Official EUVD identifiers, advisory evidence and known-exploited context. Missing fields are not treated as evidence of low risk.

1 current
ENISA EUVD identifier

EUVD-2019-16099

No EUVD known-exploited evidence

ENISA has published the identifier mapping but no EUVD description has been stored yet.

EUVD state
Present in the current official mapping
Known exploitation
Not present in the current ENISA EUVD known-exploited dataset. This is not proof of no exploitation.
ENISA score
Not supplied in the stored EUVD record
Advisory evidence
No linked advisory details stored yet
Recommended actionScheduled

Medium technical severity with no CISA KEV confirmation; remediate through the normal risk-based patch cycle unless local exposure raises the priority.

Patch available
01

What, why and how

The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro ICD, Nayamed ND ICD, Primo ICD, Protecta ICD and CRT-D, Secura ICD, Virtuoso ICD, Virtuoso II ICD, Visia AF ICD, and Viva CRT-D does not implement encryption. An attacker with adjacent short-range access to a target product can listen to communications, including the transmission of sensitive data.

What

The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro ICD, Nayamed ND ICD, Primo ICD, Protecta ICD and CRT-D, Secura ICD, Virtuoso ICD, Virtuoso II ICD, Visia AF ICD, and Viva CRT-D does not implement encryption. An attacker with adjacent short-range access to a target product can listen to communications, including the transmission of sensitive data.

Why

The product transmits sensitive or security-critical data in cleartext in a communication channel that can be sniffed by unauthorized actors.

How

An attacker operating through an adjacent network may attempt exploitation without authentication or user interaction. If successful, the issue may cause the confidentiality, integrity or availability impact described by the vendor.

What

The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro ICD, Nayamed ND ICD, Primo ICD, Protecta ICD and CRT-D, Secura ICD, Virtuoso ICD, Virtuoso II ICD, Visia AF ICD, and Viva CRT-D does not implement encryption. An attacker with adjacent short-range access to a target product can listen to communications, including the transmission of sensitive data.

Why

The product transmits sensitive or security-critical data in cleartext in a communication channel that can be sniffed by unauthorized actors.

How

An attacker operating through an adjacent network may attempt exploitation without authentication or user interaction. If successful, the issue may cause the confidentiality, integrity or availability impact described by the vendor.

02

Exploit reality and attack path

CVSS severity, EPSS forecast probability, public exploit material and CISA-confirmed exploitation are separate signals.

Observed exploitation
?Confirmed exploitation and public exploit material are separate signals. Attacks can occur without public proof-of-concept or exploit code.
No confirmed evidence

No CISA KEV match was present at the last successful refresh. This means no confirmation from that source, not proof of no exploitation.

Public PoC / exploit material
?Confirmed exploitation and public exploit material are separate signals. Attacks can occur without public proof-of-concept or exploit code.
None recorded

No exploit-tagged reference or CISA SSVC proof-of-concept state is currently recorded. Research may still exist outside the structured feeds.

Likely attack path
an adjacent network → Cleartext Transmission of Sensitive Information → cause the confidentiality, integrity or availability impact described by the vendor
Attack surface
Adjacent
Privileges required
None: unauthenticated exploitation is possible
User interaction
None
Attack complexity
Low: no specialised conditions are recorded
Security boundary
Unchanged: impact remains within the vulnerable component's security authority
Weakness
?CWE means Common Weakness Enumeration: a standard category for the underlying weakness.
CWE-319

CWE-319: Cleartext Transmission of Sensitive Information. The product transmits sensitive or security-critical data in cleartext in a communication channel that can be sniffed by unauthorized actors.

CVSS vector
?CVSS means Common Vulnerability Scoring System. The vector records the metric values used to calculate technical severity.
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

Common Vulnerability Scoring System 3.1: the compact vector below is decoded into plain language.

AVAdjacentAttack vector: The attacker must be on an adjacent or logically close network.ACLowAttack complexity: No specialised conditions are required beyond attacker-controlled input.PRNonePrivileges required: The attacker does not need an account or existing privileges.UINoneUser interaction: No action by another user is required.SUnchangedScope: The security impact remains within the vulnerable component's authority.CHighConfidentiality impact: A successful attack can cause a major loss.INoneIntegrity impact: No direct loss is represented by this metric.ANoneAvailability impact: No direct loss is represented by this metric.
Post-exploitation / living off the land
No specific living-off-the-land technique is confirmed in the structured sources. Monitor normal administration tools for activity inconsistent with the affected service's baseline.
UnauthenticatedCWE-319
A

Official authority intelligence

Only matched European and national findings are included. Language selectors and unavailable sources are omitted.

03

Patch and workaround

Operational remediation based on structured source evidence.

Status
?Patch availability is based on structured fixed-version fields and authoritative update references. If no fix is verified, check the vendor advisory before making a change.
Patch available
Affected
Conexus Radio Frequency Telemetry Protocol: All versions; MyCareLink Monitor: 24950, 24952; CareLink Monitor: 2490C; CareLink 2090 Programmer: All versions; Amplia CRT-D: All versions; Claria CRT-D: All versions; Compia CRT-D: All versions; Concerto CRT-D: All versions; Concerto II CRT-D: All versions; Consulta CRT-D: All versions; Evera ICD: All versions; Maximo II CRT-D: All versions; Maximo II ICD: All versions; Mirro ICD: All versions; Nayamed ND ICD: All versions; Primo ICD: All versions; Protecta ICD, Protecta CRT-D: All versions; Secura ICD: All versions; Virtuoso ICD: All versions; Virtuoso II ICD: All versions; Visia AF ICD: All versions; Viva CRT-D: All versions; Brava CRT-D: All versions; Mirro MRI ICD: All versions
Fixed
Medtronic has developed mitigating patches for a subset of the; affected implanted cardiac device models. These patches are installed; during regular office visits. Medtronic has stated that patches for; additional impacted models are being developed by Medtronic and will be; deployed through future updates. Patches are currently available for the; following affected models:; * Protecta CRT-D and implantable cardioverter defibrillators (ICDs), all models; * Amplia MRI CRT-D, all models (patch available in U.S. only); * Claria MRI CRT-D, all models (patch available in U.S. only); * Compia MRI CRT-D, all models (patch available in U.S. only); * Visia AF MRI ICD, all models; * Visia AF ICD, all models
Action
Review the linked authoritative reference and apply the recorded fixed release appropriate to the affected product branch.
Workaround
No verified workaround is recorded. Limit untrusted access and use least privilege until authoritative guidance is available.
04

Evidence and provenance

Published 26 Mar 2019 · Last source change 22 May 2025, 19:23 UTC · CWE-319 · Cleartext Transmission of Sensitive Information

CVE recordCVE.org · 5.1
CVSS sourceCNA
EPSS source
?The date BlackTree first stored a score for this CVE from the daily FIRST EPSS feed.
FIRST · tracked since 2026-09-01
European sourceENISA EUVD · EUVD-2019-16099
Product sourceCNA
Remediation sourceCVE/CNA references
CWE sourceCNA
NVD statusNVD modified after enrichment

Core structured fields are present and their contributing authorities are shown above.

Material change intelligence

What changed after publication

View recent updates →
  1. ENISA EUVD mappingEUVD-2019-16099 was added to the official ENISA EUVD mapping for this CVE.
    Before
    not recorded
    After
    {"euvdId":"EUVD-2019-16099"}
    ENISA EUVD
  2. Catalogue recordCVE added to the BlackTree catalogue.
    CNA
Material fields only · duplicate refreshes suppressed · history retained for the configured operational retention period
Technical terms and abbreviations used in this report
CVE
Common Vulnerabilities and Exposures: the public identifier for one disclosed vulnerability.
CVSS
Common Vulnerability Scoring System: a technical severity framework; it is not patching priority by itself.
EPSS
Exploit Prediction Scoring System: FIRST's estimate of the probability that exploitation activity will be observed in the next 30 days; it is a forecast, not confirmation.
CWE
Common Weakness Enumeration: the standard category describing the underlying software or hardware weakness.
CNA
CVE Numbering Authority: an organisation authorised to assign and publish CVE records.
CISA ADP
Cybersecurity and Infrastructure Security Agency Authorized Data Publisher: structured enrichment added to a CVE record.
NVD
National Vulnerability Database: NIST's enrichment service for CVE records.
CERT / CSIRT
A computer security incident response team that publishes warnings or coordinates incident response.
PoC
Proof of concept: public material that demonstrates or helps reproduce exploitation.
CSAF
Common Security Advisory Framework: a machine-readable format for security advisories.
LoTL
Living off the land: abuse of legitimate tools or system functions during an attack.
Free version - for non-commercial use only.CVE-2019-6540 · cve.blacktree.nl