The vendor explicitly identifies these products as affected by this CVE.
- Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller
- Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200
- Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P
- PROFINET Driver for Controller
- RUGGEDCOM RM1224 family (6GK6108-4AM00)
- SCALANCE M804PB (6GK5804-0AP00-2AA2)
- SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2)
- SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2)
- SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2)
- SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2)
- SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2)
- SCALANCE M874-2 (6GK5874-2AA00-2AA2)
- Summary
- Profinet-IO (PNIO) stack versions prior V06.00 do not properly limit internal resource allocation when multiple legitimate diagnostic package requests are sent to the DCE-RPC interface. This could lead to a denial of service condition due to lack of memory for devices that include a vulnerable version of the stack. The security vulnerability could be exploited by an attacker with network access to an affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise the availability of the device.
- Remediation
- Update to V3.3 or later version