BlackTreeIndependent security intelligence
← Back to the CVE catalogue
Full vulnerability report · 2020
CVE-2019-13933High confidence

Siemens SCALANCE X204RNA (HSR) — Missing Authentication for Critical Function

Siemens · SCALANCE X204RNA (HSR)

8.6HighCVSS 3.1
Recommended action
Within 7 days

High technical severity; prioritise exposed affected systems while verifying vendor guidance.

Patch available
Direct vendor intelligence

Authoritative vendor CSAF and VEX advisories

Structured product status and remediation from the issuing vendor. Product-state explanations are always visible; large lists can be searched or downloaded.

1 current
SSA-443566 · CSAF 2.0 · revision 4 · finalSiemens ProductCERTSSA-443566: Authentication Bypass in SCALANCE X Switches Families
80 known affected

The vendor explicitly identifies these products as affected by this CVE.

  • SCALANCE X204RNA (HSR) (6GK5204-0BA00-2MB2)
  • SCALANCE X204RNA (PRP) (6GK5204-0BA00-2KB2)
  • SCALANCE X204RNA EEC (HSR) (6GK5204-0BS00-2NA3)
  • SCALANCE X204RNA EEC (PRP) (6GK5204-0BS00-3LA3)
  • SCALANCE X204RNA EEC (PRP/HSR) (6GK5204-0BS00-3PA3)
  • SCALANCE X302-7 EEC (230V, coated) (6GK5302-7GD00-3GA3)
  • SCALANCE X302-7 EEC (230V) (6GK5302-7GD00-3EA3)
  • SCALANCE X302-7 EEC (24V, coated) (6GK5302-7GD00-1GA3)
  • SCALANCE X302-7 EEC (24V) (6GK5302-7GD00-1EA3)
  • SCALANCE X302-7 EEC (2x 230V, coated) (6GK5302-7GD00-4GA3)
  • SCALANCE X302-7 EEC (2x 230V) (6GK5302-7GD00-4EA3)
  • SCALANCE X302-7 EEC (2x 24V, coated) (6GK5302-7GD00-2GA3)
Summary
Affected devices contain a vulnerability that allows an unauthenticated attacker to violate access-control rules. The vulnerability can be triggered by sending GET request to specific uniform resource locator on the web configuration interface of the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. An attacker could use the vulnerability to obtain sensitive information or change the device configuration. At the time of advisory publication no public exploitation of this security vulnerability was known.
Remediation
Update to V3.2.7 or later version
Optional official sources

National CERT insights
?CERT means Computer Emergency Response Team; CSIRT is the closely related term Computer Security Incident Response Team.

Select the national-authority views to include. The exact source language is shown on each matched advisory. Your choice is remembered on this device and encoded in the shareable URL.

Official European source

ENISA European Vulnerability Database

Official EUVD identifiers, advisory evidence and known-exploited context. Missing fields are not treated as evidence of low risk.

1 current
ENISA EUVD identifier

EUVD-2019-5202

No EUVD known-exploited evidence

ENISA has published the identifier mapping but no EUVD description has been stored yet.

EUVD state
Present in the current official mapping
Known exploitation
Not present in the current ENISA EUVD known-exploited dataset. This is not proof of no exploitation.
ENISA score
Not supplied in the stored EUVD record
Advisory evidence
No linked advisory details stored yet
Recommended actionWithin 7 days

High technical severity; prioritise exposed affected systems while verifying vendor guidance.

Patch available
01

What, why and how

A vulnerability has been identified in SCALANCE X204RNA (HSR), SCALANCE X204RNA (PRP), SCALANCE X204RNA EEC (HSR), SCALANCE X204RNA EEC (PRP), SCALANCE X204RNA EEC (PRP/HSR), SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. Affected devices contain a vulnerability that allows an unauthenticated attacker to violate access-control rules. The vulnerability can be triggered by sending GET request to specific uniform resource locator on the web configuration interface of the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. An attacker could use the vulnerability to obtain sensitive information or change the device configuration. At the time of advisory publication no public exploitation of this security vulnerability was known.

What

A vulnerability has been identified in SCALANCE X204RNA (HSR), SCALANCE X204RNA (PRP), SCALANCE X204RNA EEC (HSR), SCALANCE X204RNA EEC (PRP), SCALANCE X204RNA EEC (PRP/HSR), SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. Affected devices contain a vulnerability that allows an unauthenticated attacker to violate access-control rules. The vulnerability can be triggered by sending GET request to specific uniform resource locator on the web configuration interface of the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. An attacker could use the vulnerability to obtain sensitive information or change the device configuration. At the time of advisory publication no public exploitation of this security vulnerability was known.

Why

A security-sensitive function is reachable without the authentication check that should protect it.

How

An attacker operating through a network path may attempt exploitation without authentication or user interaction. If successful, the issue may obtain information outside the intended access boundary.

What

A vulnerability has been identified in SCALANCE X204RNA (HSR), SCALANCE X204RNA (PRP), SCALANCE X204RNA EEC (HSR), SCALANCE X204RNA EEC (PRP), SCALANCE X204RNA EEC (PRP/HSR), SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. Affected devices contain a vulnerability that allows an unauthenticated attacker to violate access-control rules. The vulnerability can be triggered by sending GET request to specific uniform resource locator on the web configuration interface of the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. An attacker could use the vulnerability to obtain sensitive information or change the device configuration. At the time of advisory publication no public exploitation of this security vulnerability was known.

Why

A security-sensitive function is reachable without the authentication check that should protect it.

How

An attacker operating through a network path may attempt exploitation without authentication or user interaction. If successful, the issue may obtain information outside the intended access boundary.

02

Exploit reality and attack path

CVSS severity, EPSS forecast probability, public exploit material and CISA-confirmed exploitation are separate signals.

Observed exploitation
?Confirmed exploitation and public exploit material are separate signals. Attacks can occur without public proof-of-concept or exploit code.
No confirmed evidence

No CISA KEV match was present at the last successful refresh. This means no confirmation from that source, not proof of no exploitation.

Public PoC / exploit material
?Confirmed exploitation and public exploit material are separate signals. Attacks can occur without public proof-of-concept or exploit code.
None recorded

No exploit-tagged reference or CISA SSVC proof-of-concept state is currently recorded. Research may still exist outside the structured feeds.

Likely attack path
a network path → Missing Authentication for Critical Function → obtain information outside the intended access boundary
Attack surface
Network
Privileges required
None: unauthenticated exploitation is possible
User interaction
None
Attack complexity
Low: no specialised conditions are recorded
Security boundary
Unchanged: impact remains within the vulnerable component's security authority
Weakness
?CWE means Common Weakness Enumeration: a standard category for the underlying weakness.
CWE-306

CWE-306: Missing Authentication for Critical Function. The product does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources.

CVSS vector
?CVSS means Common Vulnerability Scoring System. The vector records the metric values used to calculate technical severity.
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:L

Common Vulnerability Scoring System 3.1: the compact vector below is decoded into plain language.

AVNetworkAttack vector: The vulnerable component can be reached over a network.ACLowAttack complexity: No specialised conditions are required beyond attacker-controlled input.PRNonePrivileges required: The attacker does not need an account or existing privileges.UINoneUser interaction: No action by another user is required.SUnchangedScope: The security impact remains within the vulnerable component's authority.CLowConfidentiality impact: A successful attack can cause a limited loss.IHighIntegrity impact: A successful attack can cause a major loss.ALowAvailability impact: A successful attack can cause a limited loss.
Post-exploitation / living off the land
No specific living-off-the-land technique is confirmed in the structured sources. Monitor normal administration tools for activity inconsistent with the affected service's baseline.
NetworkUnauthenticatedCWE-306
A

Official authority intelligence

Only matched European and national findings are included. Language selectors and unavailable sources are omitted.

CERT-FR · French · CERTFR-2022-AVI-124Multiples vulnérabilités dans les produits Siemens

cord?id=CVE-2017-2681 Référence CVE CVE-2017-6458 https://www.cve.org/CVERecord?id=CVE-2017-6458 Référence CVE CVE-2018-18065 https://www.cve.org/CVERecord?id=CVE-2018-18065 Référence CVE CVE-2019-10923 https://www.cve.org/CVERecord?id=CVE-2019-10923 Référence CVE CVE-2019-10936 https://www.cve.org/CVERecord?id=CVE-2019-10936 Référence CVE CVE-2019-10942 https://www.cve.org/CVERecord?id=CVE-2019-10942 Référence CVE CVE-2019-11477 https://www.cve.org/CVERecord?id=CVE-2019-11477 Référence CVE CVE-2019-11478 https://www.cve.org/CVERecord?id=CVE-2019-11478 Référence CVE CVE-2019-11479 https://www.cve.org/CVERecord?id=CVE-2019-11479 Référence CVE CVE-2019-13933 https://www.cve.org/CVERecord?id=CVE-2019-13933 Référence CVE CVE-2019-13946 https://www.cve.org/CVERecord?id=CVE-2019-13946 Référence CVE CVE-2019-19300 https://www.cve.org/CVERecord?id=CVE-2019-19300 Référence CVE CVE-2019-19301 https://www.cve.org/CVERecord?id=CVE-2019-19301 Référence CVE CVE-2019-6568 https://www.cve.org/CVERecord?id=CVE-2019-6568 Référence CVE CVE-2019-6575 https://www.cve.org/CVERecord?id=CVE-2019-6575 Référence CVE CVE-2019-8460 https://www.cve.org/CVERecord?id=CVE-2019-8460 Référence CVE CVE-2020-12357 https://www.cve.org/CVERecord?id=CVE-2020-12357 Référence CVE CVE-2020-12358 https://www.cve.org/CVERecord?id=CVE-20

Official advisory
CERT-FR · French · CERTFR-2020-AVI-023Multiples vulnérabilités dans les produits Siemens

De multiples vulnérabilités ont été découvertes dans les produits Siemens. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un contournement de la politique de sécurité et une atteinte à l'intégrité des données.

Official advisory
03

Patch and workaround

Operational remediation based on structured source evidence.

Status
?Patch availability is based on structured fixed-version fields and authoritative update references. If no fix is verified, check the vendor advisory before making a change.
Patch available
Affected
SCALANCE X204RNA (HSR) (6GK5204-0BA00-2MB2); SCALANCE X204RNA (PRP) (6GK5204-0BA00-2KB2); SCALANCE X204RNA EEC (HSR) (6GK5204-0BS00-2NA3); SCALANCE X204RNA EEC (PRP) (6GK5204-0BS00-3LA3); SCALANCE X204RNA EEC (PRP/HSR) (6GK5204-0BS00-3PA3); SCALANCE X302-7 EEC (230V, coated) (6GK5302-7GD00-3GA3); SCALANCE X302-7 EEC (230V) (6GK5302-7GD00-3EA3); SCALANCE X302-7 EEC (24V, coated) (6GK5302-7GD00-1GA3); SCALANCE X302-7 EEC (24V) (6GK5302-7GD00-1EA3); SCALANCE X302-7 EEC (2x 230V, coated) (6GK5302-7GD00-4GA3); SCALANCE X302-7 EEC (2x 230V) (6GK5302-7GD00-4EA3); SCALANCE X302-7 EEC (2x 24V, coated) (6GK5302-7GD00-2GA3); SCALANCE X302-7 EEC (2x 24V) (6GK5302-7GD00-2EA3); SCALANCE X304-2FE (6GK5304-2BD00-2AA3); SCALANCE X306-1LD FE (6GK5306-1BF00-2AA3); SCALANCE X307-2 EEC (230V, coated) (6GK5307-2FD00-3GA3); SCALANCE X307-2 EEC (230V) (6GK5307-2FD00-3EA3); SCALANCE X307-2 EEC (24V, coated) (6GK5307-2FD00-1GA3); SCALANCE X307-2 EEC (24V) (6GK5307-2FD00-1EA3); SCALANCE X307-2 EEC (2x 230V, coated) (6GK5307-2FD00-4GA3); SCALANCE X307-2 EEC (2x 230V) (6GK5307-2FD00-4EA3); SCALANCE X307-2 EEC (2x 24V, coated) (6GK5307-2FD00-2GA3); SCALANCE X307-2 EEC (2x 24V) (6GK5307-2FD00-2EA3); SCALANCE X307-3 (6GK5307-3BL00-2AA3); SCALANCE X307-3 (6GK5307-3BL10-2AA3); SCALANCE X307-3LD (6GK5307-3BM00-2AA3); SCALANCE X307-3LD (6GK5307-3BM10-2AA3); SCALANCE X308-2 (6GK5308-2FL00-2AA3); SCALANCE X308-2 (6GK5308-2FL10-2AA3); SCALANCE X308-2LD (6GK5308-2FM00-2AA3); and 50 more
Fixed
No fixed version is explicitly recorded in the structured CVE data.
Action
Update to V3.2.7 or later version
Workaround
No verified workaround is recorded. If business-safe, reduce exposure to the affected interface and allow only trusted sources until authoritative guidance is available.
04

Evidence and provenance

Published 16 Jan 2020 · Last source change 5 Aug 2024, 00:05 UTC · CWE-306 · Missing Authentication for Critical Function

CVE recordCVE.org · 5.1
CVSS sourceNIST NVD
EPSS source
?The date BlackTree first stored a score for this CVE from the daily FIRST EPSS feed.
FIRST · tracked since 2026-08-14
European sourceENISA EUVD · EUVD-2019-5202
Product sourceVendor CSAF · Siemens ProductCERT
Remediation sourceVendor CSAF · Siemens ProductCERT
CWE sourceCNA
NVD statusNVD modified after enrichment

Core structured fields are present and their contributing authorities are shown above.

Material change intelligence

What changed after publication

View recent updates →

No material field changes have been recorded since change tracking began. Routine source refreshes and cosmetic edits are intentionally excluded.

Material fields only · duplicate refreshes suppressed · history retained for the configured operational retention period
Technical terms and abbreviations used in this report
CVE
Common Vulnerabilities and Exposures: the public identifier for one disclosed vulnerability.
CVSS
Common Vulnerability Scoring System: a technical severity framework; it is not patching priority by itself.
EPSS
Exploit Prediction Scoring System: FIRST's estimate of the probability that exploitation activity will be observed in the next 30 days; it is a forecast, not confirmation.
CWE
Common Weakness Enumeration: the standard category describing the underlying software or hardware weakness.
CNA
CVE Numbering Authority: an organisation authorised to assign and publish CVE records.
CISA ADP
Cybersecurity and Infrastructure Security Agency Authorized Data Publisher: structured enrichment added to a CVE record.
NVD
National Vulnerability Database: NIST's enrichment service for CVE records.
CERT / CSIRT
A computer security incident response team that publishes warnings or coordinates incident response.
PoC
Proof of concept: public material that demonstrates or helps reproduce exploitation.
CSAF
Common Security Advisory Framework: a machine-readable format for security advisories.
LoTL
Living off the land: abuse of legitimate tools or system functions during an attack.
Free version - for non-commercial use only.CVE-2019-13933 · cve.blacktree.nl