Evidence used
- No CISA KEV confirmation is currently recorded.
- The selected CVSS metric records a network-reachable, unauthenticated path with no user interaction.
- EPSS is 1.49% for the current model date.
BlackTreeCVE IntelligenceSiemens AG · SIPROTEC 5 devices with CPU variants CP200
Critical technical impact with a remotely reachable, unauthenticated path; no CISA KEV confirmation is currently recorded.
Critical technical impact with a remotely reachable, unauthenticated path; no CISA KEV confirmation is currently recorded.
Patch availableA vulnerability has been identified in SIPROTEC 5 devices with CPU variants CP200 (All versions < V7.59), SIPROTEC 5 devices with CPU variants CP300 and CP100 (All versions < V8.01), Siemens Power Meters Series 9410 (All versions < V2.2.1), Siemens Power Meters Series 9810 (All versions). An unauthenticated attacker with network access to the device could potentially insert arbitrary code which is executed before firmware verification in the device. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in SIPROTEC 5 devices with CPU variants CP200 (All versions < V7.59), SIPROTEC 5 devices with CPU variants CP300 and CP100 (All versions < V8.01), Siemens Power Meters Series 9410 (All versions < V2.2.1), Siemens Power Meters Series 9810 (All versions). An unauthenticated attacker with network access to the device could potentially insert arbitrary code which is executed before firmware verification in the device. At the time of advisory publication no public exploitation of this security vulnerability was known.
The product does not restrict or incorrectly restricts access to a resource from an unauthorized actor.
An attacker operating through a network path may attempt exploitation without authentication or user interaction. If successful, the issue may execute code or commands in the affected security context.
A vulnerability has been identified in SIPROTEC 5 devices with CPU variants CP200 (All versions < V7.59), SIPROTEC 5 devices with CPU variants CP300 and CP100 (All versions < V8.01), Siemens Power Meters Series 9410 (All versions < V2.2.1), Siemens Power Meters Series 9810 (All versions). An unauthenticated attacker with network access to the device could potentially insert arbitrary code which is executed before firmware verification in the device. At the time of advisory publication no public exploitation of this security vulnerability was known.
The product does not restrict or incorrectly restricts access to a resource from an unauthorized actor.
An attacker operating through a network path may attempt exploitation without authentication or user interaction. If successful, the issue may execute code or commands in the affected security context.
CVSS severity, EPSS forecast probability, public exploit material and CISA-confirmed exploitation are separate signals.
No CISA KEV match was present at the last successful refresh. This means no confirmation from that source, not proof of no exploitation.
No exploit-tagged reference or CISA SSVC proof-of-concept state is currently recorded. Research may still exist outside the structured feeds.
CWE-284: Improper Access Control. The product does not restrict or incorrectly restricts access to a resource from an unauthorized actor.
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:HCommon Vulnerability Scoring System 3.1: the compact vector below is decoded into plain language.
Operational remediation based on structured source evidence.
Published 2 Aug 2019 · Last source change 4 Aug 2024, 22:40 UTC · CWE-284 · Improper Access Control
Core structured fields are present and their contributing authorities are shown above.