Evidence used
- No CISA KEV confirmation is currently recorded.
- A structured source references public exploit or proof-of-concept material.
- EPSS is 3.62% for the current model date.
BlackTreeCVE IntelligenceUnknown · Unknown
High technical severity with public exploit material referenced by a structured source; prioritise exposed affected systems while verifying vendor guidance.
High technical severity with public exploit material referenced by a structured source; prioritise exposed affected systems while verifying vendor guidance.
Fix not verifiedAn issue was discovered on Tenda AC9 V15.03.05.19(6318)_CN and AC10 V15.03.06.23_CN devices. The mac parameter in a POST request is used directly in a doSystemCmd call, causing OS command injection.
An issue was discovered on Tenda AC9 V15.03.05.19(6318)_CN and AC10 V15.03.06.23_CN devices. The mac parameter in a POST request is used directly in a doSystemCmd call, causing OS command injection.
Untrusted input is incorporated into an operating-system command without safe parameter handling.
An attacker operating through a network path may attempt exploitation with low privileges. If successful, the issue may cause the confidentiality, integrity or availability impact described by the vendor.
An issue was discovered on Tenda AC9 V15.03.05.19(6318)_CN and AC10 V15.03.06.23_CN devices. The mac parameter in a POST request is used directly in a doSystemCmd call, causing OS command injection.
Untrusted input is incorporated into an operating-system command without safe parameter handling.
An attacker operating through a network path may attempt exploitation with low privileges. If successful, the issue may cause the confidentiality, integrity or availability impact described by the vendor.
CVSS severity, EPSS forecast probability, public exploit material and CISA-confirmed exploitation are separate signals.
No CISA KEV match was present at the last successful refresh. This means no confirmation from that source, not proof of no exploitation.
A structured CVE source labels at least one public reference as exploit material. BlackTree has not independently validated that it is safe, reliable or weaponised.
CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection'). The product constructs all or part of an OS command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended OS command when it is sent to a downstream component.
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:HCommon Vulnerability Scoring System 3.0: the compact vector below is decoded into plain language.
Operational remediation based on structured source evidence.
Published 2 Sept 2018 · Last source change 5 Aug 2024, 10:24 UTC · CWE-78 · Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Missing structured fields: affected product. Missing data is not evidence of low risk; review the primary advisory.