BlackTreeCVE Intelligence
← Back to the CVE catalogue
Full vulnerability report · 2017
CVE-2017-12741High confidence

Specially crafted packets sent to port 161/udp could cause a denial of service condition

Siemens · Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller

Official source article: Siemens SSA-346262 ↗. Check the applicable product and release in the original source.

8.7HighCVSS 4.0
Recommended action
Patch only the product branches with a verified fix

High technical severity; prioritise exposed affected systems while verifying vendor guidance. Verified remediation exists for at least one product or source, but 86 structured product or package states remain unresolved. Apply remediation only to the exact product branch confirmed by its source.

Fix availability varies by product
R
Operational reassessment

Published severity in operational context

Open reassessment dashboard →
Published severityHighOperational priority:High, unchanged from published severity.unchanged

Evidence used

  • No CISA KEV confirmation is currently recorded.
  • The selected CVSS metric records a network-reachable, unauthenticated path with no user interaction.
  • EPSS is 3.31% for the current model date.

Compensating controls

  • Validate the affected product branch and deploy the verified fixed release.
  • Restrict the affected network interface to trusted sources where business-safe.
  • Monitor vendor guidance and exploitation sources for a material change.

Verification

  1. Confirm that the asset runs Siemens Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller and falls inside the recorded affected range.
  2. Verify the installed build against the product-specific fixed version after deployment.
  3. Validate exposure, authentication requirements and compensating controls in the actual environment.
  4. Reopen this reassessment when CVSS, KEV, EPSS, exploit evidence or remediation changes.
Mitigation target: Within 30 daysRemediation target: Within 180 days

This automated reassessment organises public evidence. It does not know asset exposure, business impact or control effectiveness and does not replace CVSS or a human risk decision.

Cross-source reconciliation

Remediation availability differs by product scope

Verified remediation exists for at least one product or source, but 86 structured product or package states remain unresolved. Apply remediation only to the exact product branch confirmed by its source.

Direct vendor intelligence

Authoritative vendor CSAF and VEX advisories

Structured product status and remediation from the issuing vendor. Product-state explanations are always visible; large lists can be searched or downloaded.

1 current
SSA-346262 · CSAF 2.0 · revision 24 · interimSiemens ProductCERTSSA-346262: Denial of Service Vulnerability in SNMP Interface of Industrial Products
86 known affected

The vendor explicitly identifies these products as affected by this CVE.

  • Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller
  • Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200
  • Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P
  • SIMATIC Compact Field Unit
  • SIMATIC ET 200AL IM 157-1 PN (6ES7157-1AB00-0AB0)
  • SIMATIC ET 200M (incl. SIPLUS variants)
  • SIMATIC ET 200MP IM 155-5 PN BA (6ES7155-5AA00-0AA0)
  • SIMATIC ET 200MP IM 155-5 PN HF (6ES7155-5AA00-0AC0)
  • SIMATIC ET 200MP IM 155-5 PN ST (6ES7155-5AA00-0AB0)
  • SIMATIC ET 200pro IM 154-3 PN HF (6ES7154-3AB00-0AB0)
  • SIMATIC ET 200pro IM 154-4 PN HF (6ES7154-4AB10-0AB0)
  • SIMATIC ET 200SP IM 155-6 PN BA (6ES7155-6AR00-0AN0)
Summary
Specially crafted packets sent to port 161/udp could cause a denial of service condition. The affected devices must be restarted manually.
Remediation
Update to V1.0.2 or later version
Optional official sources

National CERT insights
?CERT means Computer Emergency Response Team; CSIRT is the closely related term Computer Security Incident Response Team.

Choose official national sources for this report. Each advisory shows its original language. Your selection is remembered on this device and included in shared links.

Official European source

ENISA European Vulnerability Database

Official EUVD identifiers, advisory evidence and known-exploited context. Missing fields are not treated as evidence of low risk.

1 current
ENISA EUVD identifier

EUVD-2017-4280

No EUVD known-exploited evidence

ENISA has published the identifier mapping but no EUVD description has been stored yet.

EUVD state
Present in the current official mapping
Known exploitation
Not present in the current ENISA EUVD known-exploited dataset. This is not proof of no exploitation.
ENISA score
Not supplied in the stored EUVD record
Advisory evidence
No linked advisory details stored yet
Recommended actionPatch only the product branches with a verified fix

High technical severity; prioritise exposed affected systems while verifying vendor guidance. Verified remediation exists for at least one product or source, but 86 structured product or package states remain unresolved. Apply remediation only to the exact product branch confirmed by its source.

Fix availability varies by product
01

What, why and how

Specially crafted packets sent to port 161/udp could cause a denial of service condition. The affected devices must be restarted manually.

What

Specially crafted packets sent to port 161/udp could cause a denial of service condition. The affected devices must be restarted manually.

Why

The product does not properly control the allocation and maintenance of a limited resource.

How

An attacker operating through a network path may attempt exploitation without authentication or user interaction. If successful, the issue may disrupt the affected service.

What

Specially crafted packets sent to port 161/udp could cause a denial of service condition. The affected devices must be restarted manually.

Why

The product does not properly control the allocation and maintenance of a limited resource.

How

An attacker operating through a network path may attempt exploitation without authentication or user interaction. If successful, the issue may disrupt the affected service.

02

Exploit reality and attack path

CVSS severity, EPSS forecast probability, public exploit material and CISA-confirmed exploitation are separate signals.

Observed exploitation
?Confirmed exploitation and public exploit material are separate signals. Attacks can occur without public proof-of-concept or exploit code.
No confirmed evidence

No CISA KEV match was present at the last successful refresh. This means no confirmation from that source, not proof of no exploitation.

Public PoC / exploit material
?Confirmed exploitation and public exploit material are separate signals. Attacks can occur without public proof-of-concept or exploit code.
None recorded

No exploit-tagged reference or CISA SSVC proof-of-concept state is currently recorded. Research may still exist outside the structured feeds.

Likely attack path
a network path → Uncontrolled Resource Consumption → disrupt the affected service
Attack surface
Network
Privileges required
None: unauthenticated exploitation is possible
User interaction
None
Attack complexity
Low: no specialised conditions are recorded
Security boundary
Not a CVSS 4.0 base metric
Weakness
?CWE means Common Weakness Enumeration: a standard category for the underlying weakness.
CWE-400 ↗

CWE-400: Uncontrolled Resource Consumption. The product does not properly control the allocation and maintenance of a limited resource.

CVSS vector
?CVSS means Common Vulnerability Scoring System. The vector records the metric values used to calculate technical severity.
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N

Common Vulnerability Scoring System 4.0: the compact vector below is decoded into plain language.

AVNetworkAttack vector: The vulnerable component can be reached over a network.ACLowAttack complexity: No specialised conditions are required beyond attacker-controlled input.ATNoneAttack requirements: No additional deployment or execution condition is required.PRNonePrivileges required: The attacker does not need an account or existing privileges.UINoneUser interaction: No action by another user is required.VCNoneVulnerable-system confidentiality: No direct loss is represented by this metric.VINoneVulnerable-system integrity: No direct loss is represented by this metric.VAHighVulnerable-system availability: A successful attack can cause a major loss.SCNoneSubsequent-system confidentiality: No direct loss is represented by this metric.SINoneSubsequent-system integrity: No direct loss is represented by this metric.SANoneSubsequent-system availability: No direct loss is represented by this metric.
Post-exploitation / living off the land
No specific living-off-the-land technique is confirmed in the structured sources. Monitor normal administration tools for activity inconsistent with the affected service's baseline.
NetworkUnauthenticatedDenial of serviceCWE-400
A

Official authority intelligence

Only matched European and national findings are included. Language selectors and unavailable sources are omitted.

Canadian Centre for Cyber Security · English · AV18-045[Control systems] Siemens SIMATIC, SIMOTION and SINUMERIK Vulnerabilities

Multiple vulnerabilities were identified in Siemens SIMATIC, SIMOTION and SINUMERIK products. Exploitation of these vulnerabilities could allow a user to remotely execute arbitrary code, elevate privileges, gain unauthenticated access to sensitive data, abuse cryptographic functions and cause a denial of service under certain conditions. Affected Products: Siemens reports that the vulnerabilities affect the following Industrial PCs and BIOS versions: -SIMATIC Field-PG M3: ME prior to V6.2.61.3535, -SIMATIC Field-PG M4: BIOS prior to V18.01.06, -SIMATIC Field-PG M5: BIOS prior to V22.01.04, -SIMATIC HMI IPC677C: ME prior to V6.2.61.3535, -SIMATIC IPC427D: BIOS prior to V17.0?.10, -SIMATIC IPC427E: BIOS prior to V21.01.07, -SIMATIC IPC477D: BIOS prior to V17.0?.10, -SIMATIC IPC477D PRO: BIOS prior to V17.0?.10, -SIMATIC IPC477E: BIOS prior to V21.01.07, -SIMATIC IPC547D: ME prior to V7.1.91.3272, -SIMATIC IPC547E: ME prior to V9.1.41.3024, -SIMATIC IPC547G: ME prior to V11.8.50.3425 and BIOS Siemens reports that the vulnerability affects the following versions of SIMATIC Industrial PCs using a version of Infineon’s Trusted Platform Module (TPM): -SIMATIC Field-PG M5 all versions prior to v22.01.04, -SIMATIC IPC227E all versions prior to v20.01.10, -SIMATIC IPC277E all versions prior to v20.01.10, -SIMATIC IPC427E all versions prior to v21.01.07, -SIMATIC IPC477E all versions prior to v21.01.07, -SIMATIC IPC547G all versions, and -SIMATIC ITP1000 all versions prior to v23.01.03 Siemens reports that the vulnerabilities affect the following versions of SIMATIC WinCC Add-On: -SIMATIC WinCC Add-On Historian CONNECT ALARM all versions prior to and including v5.x, -SIMATIC WinCC Add-On PI CONNECT ALARM all versions prior to and including v2.x, -SIMATIC WinCC Add-On PI CONNECT AUDIT TRAIL all versions prior to and including v1.x, -SIMATIC WinCC Add-On PM-AGENT all versions prior to and including v5.x, -SIMATIC WinCC Add-On PM-ANALYZE all versions prior to and including v7.x, -SIMATIC WinCC Add-On PM-CONTROL all versions prior to and including v10.x, -SIMATIC WinCC Add-On PM-MAINT all versions prior to and including v9.x, -SIMATIC WinCC Add-On PM-OPEN EXPORT all versions prior to and including v7.x, -SIMATIC WinCC Add-On PM-OPEN HOST-S all versions prior to and including v7.x, -SIMATIC WinCC Add-On PM-OPEN IMPORT all versions prior to and including v6.x, -SIMATIC WinCC Add-On PM-OPEN PI all versions prior to and including v7.x, -SIMATIC WinCC Add-On PM-OPEN PV02 all versions prior to and including v1.x, -SIMATIC WinCC Add-On PM-OPEN TCP/IP all versions prior to and including v8.x, -SIMATIC WinCC Add-On PM-QUALITY all versions prior to and including v9.x, -SIMATIC WinCC Add-On SICEMENT IT MIS all versions prior to and including v7.x, and -SIMATIC WinCC Add-On SIPAPER IT MIS all versions prior to and including v7.x Siemens reports the vulnerability affects the following industrial products: -SIMATIC S7-200 Smart: All versions prior to V2.03.01, -SIMATIC S7-400 PN V6: All versions prior to V6.0.6, -SIMATIC S7-400 H V6: All versions prior to V6.0.8, -SIMATIC S7-400 PN/DP V7: All versions prior to V7.0.2, -SIMATIC S7-410 V8: All versions, -SIMATIC S7-300: All versions, -SIMATIC S7-1200: All versions, -SIMATIC S7-1500: All versions prior to V2.0, -SIMATIC S7-1500 Software Controller: All versions prior to V2.0, -SIMATIC WinAC RTX 2010 incl. F: All versions, -SIMATIC ET 200 Interface modules for PROFINET IO:-SIMATIC ET 200AL: All versions, -SIMATIC ET 200ecoPN: All versions, -SIMATIC ET 200M: All versions, -SIMATIC ET 200MP IM155-5 PN BA: All versions prior to V4.0.2, -SIMATIC ET 200MP IM155-5 PN ST: All versions prior to V4.1, -SIMATIC ET 200MP (except IM155-5 PN BA and IM155-5 PN ST): All versions, -SIMATIC ET 200pro: All versions, -SIMATIC ET 200S: All versions, and -SIMATIC ET 200SP: All versions. -Development/Evaluation Kits for PROFINET IO:-DK Standard Ethernet Controller: All versions prior to V4.1.1 Patch 05, -EK-ERTEC 200P: All versions prior to V4.5, and -EK-ERTEC 200 PN IO: All versions prior to V4.5 -SIMOTION Firmware:-SIMOTION D: All versions prior to V5.1 HF1, -SIMOTION C: All versions prior to V5.1 HF1, -SIMOTION P V4.4 and V4.5: All versions prior to V4.5 HF5, and -SIMOTION P V5: All versions prior to V5.1 HF1 -SINAMICS:-SINAMICS DCM: All versions, -SINAMICS DCP: All versions, -SINAMICS G110M / G120(C/P/D) w. PN: All versions prior to V4.7 SP9 HF1, -SINAMICS G130 and G150 w. PN: All versions, -SINAMICS S110 w. PN: All versions prior to V4.4 SP3 HF6, -SINAMICS S120 w. PN: All versions prior to V4.8 HF5, -SINAMICS S150 w. PN:-V4.7: All versions, and -V4.8: All versions. -SINAMICS V90 w. PN: All versions prior to V1.02 -SINUMERIK 840D sl: All versions, -SIMATIC Compact Field Unit: All versions, -SIMATIC PN/PN Coupler: All versions, -SIMOCODE pro V PROFINET: All versions, and -SIRIUS Soft starter 3RW44 PN: All versions. CVE References: CVE-2017-5705, CVE-2017-5706, CVE-2017-5707, CVE-2017-5708, CVE-2017-5709, CVE-2017-5710, CVE-2017-5711, CVE-2017-5712, CVE-2017-15361, CVE-2017-12741

Official advisory ↗
CERT-FR · French · CERTFR-2024-AVI-0552Multiples vulnérabilités dans les produits Siemens

De multiples vulnérabilités ont été découvertes dans les produits Siemens. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et une atteinte à la confidentialité des données.

Official advisory ↗
CERT-FR · French · CERTFR-2022-AVI-124Multiples vulnérabilités dans les produits Siemens

.cve.org/CVERecord?id=CVE-2016-1550 Référence CVE CVE-2016-2518 https://www.cve.org/CVERecord?id=CVE-2016-2518 Référence CVE CVE-2016-4953 https://www.cve.org/CVERecord?id=CVE-2016-4953 Référence CVE CVE-2016-4954 https://www.cve.org/CVERecord?id=CVE-2016-4954 Référence CVE CVE-2016-4955 https://www.cve.org/CVERecord?id=CVE-2016-4955 Référence CVE CVE-2016-4956 https://www.cve.org/CVERecord?id=CVE-2016-4956 Référence CVE CVE-2016-7431 https://www.cve.org/CVERecord?id=CVE-2016-7431 Référence CVE CVE-2016-7433 https://www.cve.org/CVERecord?id=CVE-2016-7433 Référence CVE CVE-2016-9042 https://www.cve.org/CVERecord?id=CVE-2016-9042 Référence CVE CVE-2017-12741 https://www.cve.org/CVERecord?id=CVE-2017-12741 Référence CVE CVE-2017-2680 https://www.cve.org/CVERecord?id=CVE-2017-2680 Référence CVE CVE-2017-2681 https://www.cve.org/CVERecord?id=CVE-2017-2681 Référence CVE CVE-2017-6458 https://www.cve.org/CVERecord?id=CVE-2017-6458 Référence CVE CVE-2018-18065 https://www.cve.org/CVERecord?id=CVE-2018-18065 Référence CVE CVE-2019-10923 https://www.cve.org/CVERecord?id=CVE-2019-10923 Référence CVE CVE-2019-10936 https://www.cve.org/CVERecord?id=CVE-2019-10936 Référence CVE CVE-2019-10942 https://www.cve.org/CVERecord?id=CVE-2019-10942 Référence CVE CVE-2019-11477 https://www.cve.org/CVERecord?id=CVE-20

Official advisory ↗
CERT-FR · French · CERTFR-2020-AVI-077Multiples vulnérabilités dans les produits Siemens de variante SIPLUS

.cve.org/CVERecord?id=CVE-2015-2177 Référence CVE CVE-2015-5698 https://www.cve.org/CVERecord?id=CVE-2015-5698 Référence CVE CVE-2015-8214 https://www.cve.org/CVERecord?id=CVE-2015-8214 Référence CVE CVE-2016-2200 https://www.cve.org/CVERecord?id=CVE-2016-2200 Référence CVE CVE-2016-2201 https://www.cve.org/CVERecord?id=CVE-2016-2201 Référence CVE CVE-2016-2846 https://www.cve.org/CVERecord?id=CVE-2016-2846 Référence CVE CVE-2016-3949 https://www.cve.org/CVERecord?id=CVE-2016-3949 Référence CVE CVE-2016-8561 https://www.cve.org/CVERecord?id=CVE-2016-8561 Référence CVE CVE-2016-8562 https://www.cve.org/CVERecord?id=CVE-2016-8562 Référence CVE CVE-2017-12741 https://www.cve.org/CVERecord?id=CVE-2017-12741 Référence CVE CVE-2017-2680 https://www.cve.org/CVERecord?id=CVE-2017-2680 Référence CVE CVE-2018-13807 https://www.cve.org/CVERecord?id=CVE-2018-13807 Référence CVE CVE-2018-16556 https://www.cve.org/CVERecord?id=CVE-2018-16556 Référence CVE CVE-2018-16557 https://www.cve.org/CVERecord?id=CVE-2018-16557 Référence CVE CVE-2018-16558 https://www.cve.org/CVERecord?id=CVE-2018-16558 Référence CVE CVE-2018-16559 https://www.cve.org/CVERecord?id=CVE-2018-16559 Référence CVE CVE-2018-16561 https://www.cve.org/CVERecord?id=CVE-2018-16561 Référence CVE CVE-2018-4850 https://www.cve.org/CVERecord?id=CVE

Official advisory ↗
CERT-FR · French · CERTFR-2019-AVI-151SCADA Multiples vulnérabilités dans les produits Siemens

De multiples vulnérabilités ont été découvertes dans les produits Siemens. Elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.

Official advisory ↗
CERT-FR · French · CERTFR-2018-AVI-213Multiples vulnérabilités dans SCADA les produits Siemens

De multiples vulnérabilités ont été découvertes dans SCADA les produits Siemens . Certaines d'entre elles permettent à un attaquant de provoquer un déni de service à distance, une atteinte à l'intégrité des données et une atteinte à la confidentialité des données.

Official advisory ↗
CERT-FR · French · CERTFR-2017-AVI-428Vulnérabilité dans SCADA les produits Siemens

Une vulnérabilité a été découverte dans SCADA les produits Siemens . Elle permet à un attaquant de provoquer un déni de service à distance.

Official advisory ↗
JVN iPedia · Japanese · JVNDB-2017-011798複数の Siemens 製品におけるリソースの枯渇に関する脆弱性

複数の Siemens 製品には、リソースの枯渇に関する脆弱性が存在します。

Official advisory ↗
03

Patch and workaround

Operational remediation based on structured source evidence.

Status
?Patch availability is based on structured fixed-version fields and authoritative update references. If no fix is verified, check the vendor advisory before making a change.
Fix availability varies by product
Affected
Fixed
Update to V1.0.2 or later version
Action
Use the product-specific evidence above. Patch only products with a verified fixed release, and keep every affected or under-investigation state without a matching fix in the remediation queue.
Workaround
No verified workaround is recorded. If business-safe, reduce exposure to the affected interface and allow only trusted sources until authoritative guidance is available.
04

Evidence and provenance

Published 26 Dec 2017 · Last source change 5 Aug 2024, 18:51 UTC · CWE-400 · Uncontrolled Resource Consumption

CVE recordCVE.org · 5.1
CVSS sourceCNA
EPSS source
?The date BlackTree first stored a score for this CVE from the daily FIRST EPSS feed.
FIRST · tracked since 2026-09-01
European sourceENISA EUVD · EUVD-2017-4280
Product sourceVendor CSAF · Siemens ProductCERT
Remediation sourceVendor CSAF · Siemens ProductCERT
CWE sourceCNA
NVD statusNVD modified after enrichment

Core structured fields are present and their contributing authorities are shown above.

Material change intelligence

What changed after publication

View recent updates ↗
  1. ENISA EUVD mappingEUVD-2017-4280 was added to the official ENISA EUVD mapping for this CVE.
    Before
    not recorded
    After
    {"euvdId":"EUVD-2017-4280"}
    ENISA EUVD ↗
  2. Catalogue recordCVE added to the BlackTree catalogue.
    CNA ↗
  3. Affected versionsThe structured affected or fixed version information changed.
    Before
    All versions < V4.1.1 Patch 05; All versions < V4.5; All versions; < V1.0.2; < V4.0.2; < V4.2.0 · Fixed: No fixed version is explicitly recorded in the structured CVE data.
    After
    All versions < V4.1.1 Patch 05; All versions < V4.5; All versions; < V1.0.2; < V4.0.2; < V4.2.0 · Fixed: Update to V1.0.2 or later version
    Siemens ProductCERT ↗
  4. Remediation statusRemediation status changed from Awaiting fix to Patch available.
    Before
    Awaiting fix
    After
    Patch available
    Siemens ProductCERT ↗
Material fields only · duplicate refreshes suppressed · history retained for the configured operational retention period
Technical terms and abbreviations used in this report
CVE
Common Vulnerabilities and Exposures: the public identifier for one disclosed vulnerability.
CVSS
Common Vulnerability Scoring System: a technical severity framework; it is not patching priority by itself.
EPSS
Exploit Prediction Scoring System: FIRST's estimate of the probability that exploitation activity will be observed in the next 30 days; it is a forecast, not confirmation.
CWE
Common Weakness Enumeration: the standard category describing the underlying software or hardware weakness.
CNA
CVE Numbering Authority: an organisation authorised to assign and publish CVE records.
CISA ADP
Cybersecurity and Infrastructure Security Agency Authorized Data Publisher: structured enrichment added to a CVE record.
NVD
National Vulnerability Database: NIST's enrichment service for CVE records.
CERT / CSIRT
A computer security incident response team that publishes warnings or coordinates incident response.
PoC
Proof of concept: public material that demonstrates or helps reproduce exploitation.